    "data": {
        "id": 161574,
        "sku": "137N4855",
        "name": "IC7-60SLGC07-1040E00F4+AEZ1+AJFX+ANN1+AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+BL",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/137N4855",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 934,
            "name": "iC7-Hybrid System Modules"
        },
        "categories": [
            {
                "id": 934,
                "name": "iC7-Hybrid System Modules"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "544 Kilogram",
            "Net weight": "460 Kilogram",
            "EAN": "5715253627380",
            "Product series": "+DAHY, iC7-Hybrid",
            "Product group": "IC7-60, iC7-60",
            "Product category": "SL, System module, liquid-cooled",
            "Product type": "GC, Grid converter module, GC",
            "Salescode part 2": "+AEZ1+AJFX+ANN1, +AEZ1+AJFX+ANN1",
            "Mains voltage": "07, 525-690 V AC / 640-1100 V DC",
            "Salescode part 3": "+AO20+BAMT+BDC1+BEXX+BF20, +AO20+BAMT+BDC1+BEXX+BF20",
            "Current rating": "-1040, 1040 A",
            "Salescode part 4": "+BGK1+BH15+BK15+BL50+CAV0+CBX0, +BGK1+BH15+BK15+BL50+CAV0+CBX0",
            "Power rating": "XXX, Not relevant",
            "Salescode part 5": "+CCX0+CDX0+CEX0+CFX0+CGX0+CHX0, +CCX0+CDX0+CEX0+CFX0+CGX0+CHX0",
            "Protection rating": "E00, IP00/Open Type",
            "Salescode part 6": "+CIX0+CJX0+DAHY, +CIX0+CJX0+DAHY",
            "EMC category": "F4, C4 category",
            "Salescode part 7": "+EGIN+EHEN, +EGIN+EHEN",
            "Integration unit": "+AEZ1, Standard, with LC filter",
            "Mains input device": "+AJFX, AC fuses",
            "DC fuses and devices": "+AKXX, None",
            "Cooling circuit connector type": "+ANN1, Push-in connection",
            "Cooling circuit hose length": "+AO20, 2.0 m (6 ft)",
            "Marine construction": "+AFXX, None",
            "Extra environmental protection": "+AGCX, Coated boards",
            "Communication interface, X1/X2": "+BAMT, Modbus TCP OS7MT",
            "Communication interface, X0": "+BBEL, Ethernet port, no protocol",
            "Standard I/O": "+BDC1, I/O and Relay Option OC7C1",
            "Functional safety": "+BEXX, None, not upgradable",
            "Control panel": "+BF20, Control Panel 2.8 OPX20",
            "Control panel mounting type": "+BGK1, Flush mount",
            "Control panel cable length": "+BH15, 1.5 m (5 ft)",
            "Control unit cable length": "+BK15, 1.5 m (5 ft), Fiber",
            "StarCoupler board cable length": "+BL50, 5.0 m (16 ft), Fiber",
            "Option slot A": "+CAV0, Voltage Measurement OC7V0",
            "Option slot B": "+CBX0, None",
            "Option slot C": "+CCX0, None",
            "Option slot D": "+CDX0, None",
            "Option slot E": "+CEX0, None",
            "Option slot F": "+CFX0, None",
            "Option slot G": "+CGX0, None",
            "Option slot H": "+CHX0, None",
            "Option slot I": "+CIX0, None",
            "Option slot J": "+CJX0, None",
            "Language package": "+EL01, Global",
            "Customer specific application": "+DBXX, None",
            "Additional drive features 1": "+DD1X, None",
            "Additional drive features 2": "+DE2X, None",
            "Additional drive features 3": "+DF3X, None",
            "Additional drive features 4": "+DG4X, None",
            "Additional drive features 5": "+DH5X, None",
            "High speed enabled": "+DI6X, No",
            "Customization file package ID": "+EAXXXXXX, No customization",
            "Product software ID": "+ECXXX, Latest released version",
            "Technical documentation": "+EGIN, Installation guide",
            "Documentation language": "+EHEN, English",
            "Customer-specific label": "+EJXX, None",
            "Shipping package": "+TACB, Cardboard box package",
            "Product specific marine cert.": "+VBXX, None",
            "Frame designation": "2XAR12L, 2xAR12L",
            "Modelcode01": "IC7-60SLGC07-1040E00F4",
            "Modelcode02": "+AEZ1+AJFX+ANN1",
            "Modelcode03": "+AO20+BAMT+BDC1+BEXX+BF20",
            "Modelcode04": "+BGK1+BH15+BK15+BL50+CAV0+CBX0",
            "Modelcode05": "+CCX0+CDX0+CEX0+CFX0+CGX0+CHX0",
            "Modelcode06": "+CIX0+CJX0+DAHY",
            "Modelcode08": "+EGIN+EHEN",
            "Main unit Width": "2x235mm/9.3in, 2x235mm/9.3in",
            "Main unit Height": "1295mm/51in, 1295mm/51in",
            "Main unit Depth": "566mm/22.3in, 566mm/22.3in",
            "Calculated Gross Weight [kg]": "544",
            "Calculated Net Weight [kg]": "460",
            "ECCN EU": "Y901, Y901",
            "ECCN US": "3A999.a, 3A999.a",
            "AC voltage": "3X525-690VAC, 3X525-690VAC",
            "Apparent power": "/1104kVA(600VAC), /1104kVA(600VAC)",
            "check if complete": "OK, OK",
            "Cooling type": "Liquid Cooled, Liquid Cooled",
            "DC Bus current": "1215A(1025VDC), 1215A(1025VDC)",
            "DC Bus voltage": "640-1100VDC, 640-1100VDC",
            "DC power": "1244kW(1025VDC), 1244kW(1025VDC)",
            "Enclosure rating": "IP00 / OPEN TYPE, IP00 / OPEN TYPE",
            "Help Counter": "1",
            "High Speed Drive Warning": "NONE, NONE",
            "Input frequency": "50/60Hz, 50/60Hz",
            "Liquid temp. High Overload": "45°C/113°F, 45°C/113°F",
            "Liquid temp. Low Overload": "45°C/113°F, 45°C/113°F",
            "Liquid temp. Nominal load": "45°C/113°F, 45°C/113°F",
            "Nominal AC current": "1062A, 1062A",
            "Output frequency": "25-70Hz, 25-70Hz",
            "Power factor": "cos φ = 0 ind. to 0 cap., cos φ = 0 ind. to 0 cap.",
            "Product Catalog": "NO_VIEW, NO VIEW",
            "Product Category -DrivesSymbol": "System module, liquid-cooled, System module, liquid-cooled",
            "Product Type - DrivesSymbol": "Grid converter module, Grid converter module",
            "Product View (Switch)": "GLBL, Global (Standard)",
            "Recommended Plant": "ERR01, ERR01",
            "Salescode part 1": "IC7-60SLGC07-1040E00F4, IC7-60SLGC07-1040E00F4",
            "Short circuit current rating": "100kA, 100kA",
            "Storage temperature": "-40...70°C/-40...158°F, -40...70°C/-40...158°F",
            "Typecode Part 1": "7SM-HYSLGC07-1040E00F4",
            "Typecode Part 2": "-000134526",
            "Vendor": "ERR01, Cannot Determine Vendor"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/2f/72/2f72c94cb56b6543630a7cd89a3d2a6e9d3a873261cb8518c7bbe1045958b7e3.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/2f/72/2f72c94cb56b6543630a7cd89a3d2a6e9d3a873261cb8518c7bbe1045958b7e3.jpg",
                "local_path": "danfoss/images/2f/72/2f72c94cb56b6543630a7cd89a3d2a6e9d3a873261cb8518c7bbe1045958b7e3.jpg",
                "original_url": "https://assets.danfoss.com/drawings/218814/ID435241768508-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Connecting to iC7 Series Remotely via Mobile Network",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf"
            },
            {
                "text": "iC7 Series Grid Converter",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1b/82/1b821aa0b4b23d0ab0b41bff86b05265ac55b7aeb365286950ad412937896955.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1b/82/1b821aa0b4b23d0ab0b41bff86b05265ac55b7aeb365286950ad412937896955.pdf"
            },
            {
                "text": "iC7-Hybrid Selection Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ac/17/ac17336d7575fbcf8e9d322a895acc01a4a837bf8a2505662a10c3823a97d18f.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ac/17/ac17336d7575fbcf8e9d322a895acc01a4a837bf8a2505662a10c3823a97d18f.pdf"
            },
            {
                "text": "iC7-Marine and iC7-Hybrid Selection Guide - US English",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a8/e2/a8e26853a0b02c599c6596ebec315f430e7e9f2b6a0082bea3ebe43f94e7e83b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a8/e2/a8e26853a0b02c599c6596ebec315f430e7e9f2b6a0082bea3ebe43f94e7e83b.pdf"
            },
            {
                "text": "iC7 Series Liquid-cooled System Modules",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/92/24/9224f4eaffdb4d86053288f429da2f758750f5f0207b8248bfcc97775dd80ffd.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/92/24/9224f4eaffdb4d86053288f429da2f758750f5f0207b8248bfcc97775dd80ffd.pdf"
            },
            {
                "text": "iC7 Series Control Panel",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf"
            },
            {
                "text": "iC7 Series Liquid-cooled System Modules",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/48/f7/48f7f039d61764a2ae4bc09a9a0038e93c0f0d0b420b4b3ad9a6be7b0d2ccfd5.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/48/f7/48f7f039d61764a2ae4bc09a9a0038e93c0f0d0b420b4b3ad9a6be7b0d2ccfd5.pdf"
            },
            {
                "text": "Functional Extension Options",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf"
            },
            {
                "text": "iC7 Series Functional Safety, System Modules",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/56/17/56174dee5cf04c9ea5c0ed12b6dc9f4eb686a70581fdf2a7260f54cd468db503.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/56/17/56174dee5cf04c9ea5c0ed12b6dc9f4eb686a70581fdf2a7260f54cd468db503.pdf"
            },
            {
                "text": "iC7-Hybrid EtherCAT",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/23/5c/235c7d7729af93dccf3e7d3951568ca5dfb39dbc65d4961394b46bb46a8ea145.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/23/5c/235c7d7729af93dccf3e7d3951568ca5dfb39dbc65d4961394b46bb46a8ea145.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715253627380"
        },
        "description": "iC7-Hybrid System module, liquid-cooled IC7-60SLGC07-1040E00F4+AEZ1+AJFX+ANN1 +AO20+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+BL50+CAV0+CBX0 +CCX0+CDX0+CEX0+CFX0+CGX0+CHX0+CIX0+CJX0+DAHY +EGIN+EHEN IP00/Open Type, Frame: 2xAR12L Grid converter module, GC, 525-690 V AC / 640-1100 V DC, 1040 A EMC category: C4 category Control Panel 2.8 OPX20 Standard I/O: I/O and Relay Option OC7C1 Modbus TCP OS7MT Functional Safety: None, not upgradable Other options according to model code",
        "created_at": "2026-06-16 07:36:03",
        "variations": []
    }
}