    "data": {
        "id": 163664,
        "sku": "137N9450",
        "name": "IC7-60SAIN05-1100E00F4+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL15+CAC0+CBC1+CCX0+CD",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/137N9450",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 928,
            "name": "iC7-Automation System Modules"
        },
        "categories": [
            {
                "id": 928,
                "name": "iC7-Automation System Modules"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "160 Kilogram",
            "Net weight": "130 Kilogram",
            "EAN": "5715253676128",
            "Product series": "+DAAU, iC7-Automation",
            "Product group": "IC7-60, iC7-60",
            "Product category": "SA, System module, air-cooled",
            "Product type": "IN, Inverter module, INU",
            "Mains voltage": "05, 380-500 V AC",
            "Current rating": "-1100, 1100 A",
            "Power rating": "630, 630 kW/900 HP",
            "Salescode part 5": "+CIX0+CJX0+DAAU, +CIX0+CJX0+DAAU",
            "Protection rating": "E00, IP00/Open Type",
            "EMC category": "F4, C4 category",
            "Integration unit": "+AEXX, None",
            "Mains input device": "+AJXX, None",
            "DC fuses and devices": "+AKXX, None",
            "Communication interface, X1/X2": "+BAMT, Modbus TCP OS7MT",
            "Communication interface, X0": "+BBEL, Ethernet port, no protocol",
            "Standard I/O": "+BDC1, I/O and Relay Option OC7C1",
            "Functional safety": "+BEXX, None, not upgradable",
            "Control panel": "+BF20, Control Panel 2.8 OPX20",
            "Control panel mounting type": "+BGK1, Flush mount",
            "Control panel cable length": "+BH15, 1.5 m (5 ft)",
            "Control unit cable length": "+BK03, 0.3 m (1 ft), Fiber",
            "StarCoupler board cable length": "+BL15, 1.5 m (5 ft), Fiber",
            "Option slot A": "+CAC0, General Purpose I/O OC7C0",
            "Option slot B": "+CBC1, I/O and Relay Option OC7C1",
            "Option slot C": "+CCX0, None",
            "Option slot D": "+CDX0, None",
            "Option slot E": "+CEX0, None",
            "Option slot F": "+CFX0, None",
            "Option slot G": "+CGX0, None",
            "Option slot H": "+CHX0, None",
            "Option slot I": "+CIX0, None",
            "Option slot J": "+CJX0, None",
            "Language package": "+EL01, Global",
            "Customer specific application": "+DBXX, None",
            "Additional drive features 1": "+DD1X, None",
            "Additional drive features 2": "+DE2X, None",
            "Additional drive features 3": "+DF3X, None",
            "Additional drive features 4": "+DG4X, None",
            "Additional drive features 5": "+DH5X, None",
            "High speed enabled": "+DI6X, No",
            "Customization file package ID": "+EAXXXXXX, No customization",
            "Product software ID": "+ECXXX, Latest released version",
            "Technical documentation": "+EGXX, None",
            "Documentation language": "+EHXX, Multi-language",
            "Customer-specific label": "+EJXX, None",
            "Shipping package": "+TACB, Cardboard box package",
            "Product specific marine cert.": "+VBXX, None",
            "Frame designation": "2XIM10, 2xIM10",
            "Modelcode01": "IC7-60SAIN05-1100E00F4",
            "Modelcode03": "+BAMT+BDC1+BEXX+BF20",
            "Modelcode04": "+BGK1+BH15+BK03+BL15+CAC0+CBC1",
            "Modelcode05": "+CCX0+CDX0+CEX0+CFX0+CGX0+CHX0",
            "Modelcode06": "+CIX0+CJX0+DAAU",
            "Main unit Width": "2x170mm/6.7in, 2x170mm/6.7in",
            "Main unit Height": "990mm/39in, 990mm/39in",
            "Main unit Depth": "502mm/19.8in, 502mm/19.8in",
            "Calculated Gross Weight [kg]": "160",
            "Calculated Net Weight [kg]": "130",
            "ECCN EU": "Y901, Y901",
            "ECCN US": "3A999.a, 3A999.a",
            "AC voltage": "3X0-400/460/500VAC, 3X0-400/460/500VAC",
            "check if complete": "OK, OK",
            "Continous current IH (1/5min)": "913A(400VAC)/855A(460VAC), 913A(400VAC)/855A(460VAC)",
            "Continous current IL (1/5min)": "1100A(400VAC)/1030A(460VAC), 1100A(400VAC)/1030A(460VAC)",
            "Cooling circuit connector type": "+ANXX, Not relevant",
            "Cooling circuit hose length": "+AOXX, Not relevant",
            "Cooling type": "Air Cooled, Air Cooled",
            "DC Bus current": "1280A(540VDC), 1280A(540VDC)",
            "DC Bus voltage": "465-740VDC, 465-740VDC",
            "DC power": "691kW(540VDC), 691kW(540VDC)",
            "Enclosure rating": "IP00 / OPEN TYPE, IP00 / OPEN TYPE",
            "Extra environmental protection": "+AGCX, Coated boards",
            "Help Counter": "1",
            "High Speed Drive Warning": "NONE, NONE",
            "Marine construction": "+AFXX, None",
            "Nominal AC current": "1123A(400VAC)/1052A(460VAC), 1123A(400VAC)/1052A(460VAC)",
            "Output frequency": "0-590Hz, 0-590Hz",
            "Overload current IH (1/5min)": "1370A(400VAC)/1283A(460VAC), 1370A(400VAC)/1283A(460VAC)",
            "Overload current IL (1/5min)": "1210A(400VAC)/1133A(460VAC), 1210A(400VAC)/1133A(460VAC)",
            "Product Catalog": "NO_VIEW, NO VIEW",
            "Product Category -DrivesSymbol": "System module, air-cooled, System module, air-cooled",
            "Product Type - DrivesSymbol": "Inverter module, Inverter module",
            "Product View (Switch)": "GLBL, Global (Standard)",
            "Recommended Plant": "ERR01, ERR01",
            "Salescode part 1": "IC7-60SAIN05-1100E00F4, IC7-60SAIN05-1100E00F4",
            "Salescode part 2": "+BAMT+BDC1+BEXX+BF20, +BAMT+BDC1+BEXX+BF20",
            "Salescode part 3": "+BGK1+BH15+BK03+BL15+CAC0+CBC1, +BGK1+BH15+BK03+BL15+CAC0+CBC1",
            "Salescode part 4": "+CCX0+CDX0+CEX0+CFX0+CGX0+CHX0, +CCX0+CDX0+CEX0+CFX0+CGX0+CHX0",
            "Short circuit current rating": "100kA, 100kA",
            "Start current Imax (3sec)": "1553A, 1553A",
            "Storage temperature": "-40...70°C/-40...158°F, -40...70°C/-40...158°F",
            "Typecode Part 1": "7SM-AUSAIN05-1100E00F4",
            "Typecode Part 2": "-000139221",
            "Typical motor power PH2 (150%)": "500kW(400VAC)/650Hp(460VAC), 500kW(400VAC)/650Hp(460VAC)",
            "Typical motor power PL (110%)": "630kW(400VAC)/850Hp(460VAC), 630kW(400VAC)/850Hp(460VAC)",
            "Vendor": "ERR01, Cannot Determine Vendor"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/ef/49/ef495f17fab55b18152fd4b820b49afab40118f5098fb0c1b765ad96f0783e97.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/ef/49/ef495f17fab55b18152fd4b820b49afab40118f5098fb0c1b765ad96f0783e97.jpg",
                "local_path": "danfoss/images/ef/49/ef495f17fab55b18152fd4b820b49afab40118f5098fb0c1b765ad96f0783e97.jpg",
                "original_url": "https://assets.danfoss.com/drawings/361303/ID475652163525-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Connecting to iC7 Series Remotely via Mobile Network",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf"
            },
            {
                "text": "iC7 Series Industry; Software version 26A",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/57/93/5793442054592524eb5aea4fb9fbb6aae67086d5748cb1c5cf3d81e10dde5696.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/57/93/5793442054592524eb5aea4fb9fbb6aae67086d5748cb1c5cf3d81e10dde5696.pdf"
            },
            {
                "text": "iC7-Automation Selection Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3c/c3/3cc3923021469c6a3f73cd6ad6a92a6b562758799b56000e299a6a24330c8ba3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3c/c3/3cc3923021469c6a3f73cd6ad6a92a6b562758799b56000e299a6a24330c8ba3.pdf"
            },
            {
                "text": "iC7-Automation Selection Guide - US English",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1c/1f/1c1f1b3326c1086c18c7fd1ccf0b44486457d4488969c9a538a55cb655e3e3fc.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1c/1f/1c1f1b3326c1086c18c7fd1ccf0b44486457d4488969c9a538a55cb655e3e3fc.pdf"
            },
            {
                "text": "iC7 Series Air-cooled System Modules Design Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d6/b2/d6b2a57be51e2a0af9fabec15253f0a6823dda9261ade05463f359c48b1c051e.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d6/b2/d6b2a57be51e2a0af9fabec15253f0a6823dda9261ade05463f359c48b1c051e.pdf"
            },
            {
                "text": "iC7 Series Air-cooled Common-mode Filter OFXC1",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/96/27/96271f8808e8a6e295479e4ce503e4f3c7586fc19ead68d61c8962171176ae9d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/96/27/96271f8808e8a6e295479e4ce503e4f3c7586fc19ead68d61c8962171176ae9d.pdf"
            },
            {
                "text": "iC7 Series Air-cooled dU/dt Filter OF7U1",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f8/b7/f8b7faa6f6115630752586070b738218d3cbf93c726bc9a21974f1cd0354406b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f8/b7/f8b7faa6f6115630752586070b738218d3cbf93c726bc9a21974f1cd0354406b.pdf"
            },
            {
                "text": "iC7 Series Air-cooled LCL Filter OF7Z3 and LC Filter OF7Z1",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/8a/1a/8a1a22cc5d866aea3cdd97c402e8b827fb7d7d8dcc6d80c3ec7521219507b366.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/8a/1a/8a1a22cc5d866aea3cdd97c402e8b827fb7d7d8dcc6d80c3ec7521219507b366.pdf"
            },
            {
                "text": "iC7 Series Air-cooled System Modules Installation Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/6e/02/6e02b568b584d169f57cf7ffd65938c420bcef76e470526d3236da87eed3eebd.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/6e/02/6e02b568b584d169f57cf7ffd65938c420bcef76e470526d3236da87eed3eebd.pdf"
            },
            {
                "text": "iC7 Series Control Panel",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715253676128"
        },
        "description": "iC7-Automation System module, air-cooled IC7-60SAIN05-1100E00F4 +BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK03+BL15+CAC0+CBC1 +CCX0+CDX0+CEX0+CFX0+CGX0+CHX0+CIX0+CJX0+DAAU IP00/Open Type, Frame: 2xIM10 Inverter module, INU, 380-500 V AC, 1100 A EMC category: C4 category Control Panel 2.8 OPX20 Standard I/O: I/O and Relay Option OC7C1 Modbus TCP OS7MT Functional Safety: None, not upgradable Other options according to model code",
        "created_at": "2026-06-16 07:36:03",
        "variations": []
    }
}