    "data": {
        "id": 164977,
        "sku": "137U1600",
        "name": "IC7-60SAIN05-1260E00F4+AE01+AKFX+BAMT+BDC1+BEXX+BK25+BL25+CAX0+CBX0+CCX0+CDX0+CE",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/137U1600",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 928,
            "name": "iC7-Automation System Modules"
        },
        "categories": [
            {
                "id": 928,
                "name": "iC7-Automation System Modules"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "260 Kilogram",
            "Net weight": "220 Kilogram",
            "EAN": "5715253699196",
            "Product series": "+DAAU, iC7-Automation",
            "Product group": "IC7-60, iC7-60",
            "Product category": "SA, System module, air-cooled",
            "Product type": "IN, Inverter module, INU",
            "Mains voltage": "05, 380-500 V AC",
            "Current rating": "-1260, 1260 A",
            "Power rating": "710, 710 kW/1000 HP",
            "Salescode part 5": "+CCX0+CDX0+CEX0+CFX0+CGX0+CHX0, +CCX0+CDX0+CEX0+CFX0+CGX0+CHX0",
            "Protection rating": "E00, IP00/Open Type",
            "EMC category": "F4, C4 category",
            "Integration unit": "+AE01, Short, no filter",
            "Mains input device": "+AJXX, None",
            "DC fuses and devices": "+AKFX, DC bus fuses",
            "Communication interface, X1/X2": "+BAMT, Modbus TCP OS7MT",
            "Communication interface, X0": "+BBEL, Ethernet port, no protocol",
            "Standard I/O": "+BDC1, I/O and Relay Option OC7C1",
            "Functional safety": "+BEXX, None, not upgradable",
            "Control panel": "+BFXX, None",
            "Control panel mounting type": "+BGXX, None",
            "Control panel cable length": "+BHXX, None",
            "Control unit cable length": "+BK25, 2.5 m (8 ft), Fiber",
            "StarCoupler board cable length": "+BL25, 2.5 m (8 ft), Fiber",
            "Option slot A": "+CAX0, None",
            "Option slot B": "+CBX0, None",
            "Option slot C": "+CCX0, None",
            "Option slot D": "+CDX0, None",
            "Option slot E": "+CEX0, None",
            "Option slot F": "+CFX0, None",
            "Option slot G": "+CGX0, None",
            "Option slot H": "+CHX0, None",
            "Option slot I": "+CIX0, None",
            "Option slot J": "+CJX0, None",
            "Language package": "+EL01, Global",
            "Customer specific application": "+DBXX, None",
            "Additional drive features 1": "+DD1X, None",
            "Additional drive features 2": "+DE2X, None",
            "Additional drive features 3": "+DF3X, None",
            "Additional drive features 4": "+DG4X, None",
            "Additional drive features 5": "+DH5X, None",
            "High speed enabled": "+DI6X, No",
            "Customization file package ID": "+EAXXXXXX, No customization",
            "Product software ID": "+ECXXX, Latest released version",
            "Technical documentation": "+EGXX, None",
            "Documentation language": "+EHXX, Multi-language",
            "Customer-specific label": "+EJXX, None",
            "Shipping package": "+TACB, Cardboard box package",
            "Product specific marine cert.": "+VBXX, None",
            "Frame designation": "2XIR11, 2xIR11",
            "Modelcode01": "IC7-60SAIN05-1260E00F4",
            "Modelcode02": "+AE01+AKFX",
            "Modelcode03": "+BAMT+BDC1+BEXX",
            "Modelcode04": "+BK25+BL25+CAX0+CBX0",
            "Modelcode05": "+CCX0+CDX0+CEX0+CFX0+CGX0+CHX0",
            "Modelcode06": "+CIX0+CJX0+DAAU",
            "Main unit Width": "2x235mm/9.3in, 2x235mm/9.3in",
            "Main unit Height": "1302mm/51.3in, 1302mm/51.3in",
            "Main unit Depth": "553mm/21.8in, 553mm/21.8in",
            "Calculated Gross Weight [kg]": "260",
            "Calculated Net Weight [kg]": "220",
            "ECCN EU": "Y901, Y901",
            "ECCN US": "3A999.a, 3A999.a",
            "AC voltage": "3X0-400/460/500VAC, 3X0-400/460/500VAC",
            "check if complete": "OK, OK",
            "Continous current IH (1/5min)": "1050A(400VAC)/960A(460VAC), 1050A(400VAC)/960A(460VAC)",
            "Continous current IL (1/5min)": "1260A(400VAC)/1150A(460VAC), 1260A(400VAC)/1150A(460VAC)",
            "Cooling circuit connector type": "+ANXX, Not relevant",
            "Cooling circuit hose length": "+AOXX, Not relevant",
            "Cooling type": "Air Cooled, Air Cooled",
            "DC Bus current": "1441A(540VDC), 1441A(540VDC)",
            "DC Bus voltage": "465-740VDC, 465-740VDC",
            "DC power": "778kW(540VDC), 778kW(540VDC)",
            "Enclosure rating": "IP00 / OPEN TYPE, IP00 / OPEN TYPE",
            "Extra environmental protection": "+AGCX, Coated boards",
            "Help Counter": "1",
            "High Speed Drive Warning": "NONE, NONE",
            "Marine construction": "+AFXX, None",
            "Nominal AC current": "1287A(400VAC)/1174A(460VAC), 1287A(400VAC)/1174A(460VAC)",
            "Output frequency": "0-590Hz, 0-590Hz",
            "Overload current IH (1/5min)": "1575A(400VAC)/1440A(460VAC), 1575A(400VAC)/1440A(460VAC)",
            "Overload current IL (1/5min)": "1386A(400VAC)/1265A(460VAC), 1386A(400VAC)/1265A(460VAC)",
            "Product Catalog": "NO_VIEW, NO VIEW",
            "Product Category -DrivesSymbol": "System module, air-cooled, System module, air-cooled",
            "Product Type - DrivesSymbol": "Inverter module, Inverter module",
            "Product View (Switch)": "GLBL, Global (Standard)",
            "Recommended Plant": "ERR01, ERR01",
            "Salescode part 1": "IC7-60SAIN05-1260E00F4, IC7-60SAIN05-1260E00F4",
            "Salescode part 2": "+AE01+AKFX, +AE01+AKFX",
            "Salescode part 3": "+BAMT+BDC1+BEXX, +BAMT+BDC1+BEXX",
            "Salescode part 4": "+BK25+BL25+CAX0+CBX0, +BK25+BL25+CAX0+CBX0",
            "Salescode part 6": "+CIX0+CJX0+DAAU, +CIX0+CJX0+DAAU",
            "Short circuit current rating": "100kA, 100kA",
            "Start current Imax (3sec)": "1785A, 1785A",
            "Storage temperature": "-40...70°C/-40...158°F, -40...70°C/-40...158°F",
            "Typecode Part 1": "7SM-AUSAIN05-1260E00F4",
            "Typecode Part 2": "-000141942",
            "Typical motor power PH2 (150%)": "560kW(400VAC)/750Hp(460VAC), 560kW(400VAC)/750Hp(460VAC)",
            "Typical motor power PL (110%)": "710kW(400VAC)/950Hp(460VAC), 710kW(400VAC)/950Hp(460VAC)",
            "Vendor": "ERR01, Cannot Determine Vendor"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/ef/49/ef495f17fab55b18152fd4b820b49afab40118f5098fb0c1b765ad96f0783e97.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/ef/49/ef495f17fab55b18152fd4b820b49afab40118f5098fb0c1b765ad96f0783e97.jpg",
                "local_path": "danfoss/images/ef/49/ef495f17fab55b18152fd4b820b49afab40118f5098fb0c1b765ad96f0783e97.jpg",
                "original_url": "https://assets.danfoss.com/drawings/361303/ID475652163525-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Connecting to iC7 Series Remotely via Mobile Network",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf"
            },
            {
                "text": "iC7 Series Industry; Software version 26A",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/57/93/5793442054592524eb5aea4fb9fbb6aae67086d5748cb1c5cf3d81e10dde5696.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/57/93/5793442054592524eb5aea4fb9fbb6aae67086d5748cb1c5cf3d81e10dde5696.pdf"
            },
            {
                "text": "iC7-Automation Selection Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3c/c3/3cc3923021469c6a3f73cd6ad6a92a6b562758799b56000e299a6a24330c8ba3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3c/c3/3cc3923021469c6a3f73cd6ad6a92a6b562758799b56000e299a6a24330c8ba3.pdf"
            },
            {
                "text": "iC7-Automation Selection Guide - US English",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1c/1f/1c1f1b3326c1086c18c7fd1ccf0b44486457d4488969c9a538a55cb655e3e3fc.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1c/1f/1c1f1b3326c1086c18c7fd1ccf0b44486457d4488969c9a538a55cb655e3e3fc.pdf"
            },
            {
                "text": "iC7 Series Air-cooled System Modules Design Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d6/b2/d6b2a57be51e2a0af9fabec15253f0a6823dda9261ade05463f359c48b1c051e.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d6/b2/d6b2a57be51e2a0af9fabec15253f0a6823dda9261ade05463f359c48b1c051e.pdf"
            },
            {
                "text": "iC7 Series Air-cooled System Modules Installation Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/6e/02/6e02b568b584d169f57cf7ffd65938c420bcef76e470526d3236da87eed3eebd.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/6e/02/6e02b568b584d169f57cf7ffd65938c420bcef76e470526d3236da87eed3eebd.pdf"
            },
            {
                "text": "iC7 Series Control Panel",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf"
            },
            {
                "text": "Functional Extension Options",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf"
            },
            {
                "text": "iC7 Series Functional Safety, System Modules",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/56/17/56174dee5cf04c9ea5c0ed12b6dc9f4eb686a70581fdf2a7260f54cd468db503.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/56/17/56174dee5cf04c9ea5c0ed12b6dc9f4eb686a70581fdf2a7260f54cd468db503.pdf"
            },
            {
                "text": "iC7 Series Modbus",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d3/78/d378e2937edcdc70be81fb8c5d52ace2967211688a935918db6dfbe1acc1dfb0.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d3/78/d378e2937edcdc70be81fb8c5d52ace2967211688a935918db6dfbe1acc1dfb0.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715253699196"
        },
        "description": "iC7-Automation System module, air-cooled IC7-60SAIN05-1260E00F4+AE01+AKFX +BAMT+BDC1+BEXX+BK25+BL25+CAX0+CBX0 +CCX0+CDX0+CEX0+CFX0+CGX0+CHX0+CIX0+CJX0+DAAU IP00/Open Type, Frame: 2xIR11 Inverter module, INU, 380-500 V AC, 1260 A EMC category: C4 category None Standard I/O: I/O and Relay Option OC7C1 Modbus TCP OS7MT Functional Safety: None, not upgradable Other options according to model code",
        "created_at": "2026-06-16 07:36:03",
        "variations": []
    }
}