    "data": {
        "id": 177198,
        "sku": "148H6023",
        "name": "Gas detection unit, Basic",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/148H6023",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 994,
            "name": "Basic"
        },
        "categories": [
            {
                "id": 994,
                "name": "Basic"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "0.344 Kilogram",
            "Net weight": "0.007 Kilogram",
            "Volume": "1.012 Liter",
            "EAN": "5714279919813",
            "Type": "Basic",
            "Product group": "Sensors",
            "Product Name Description": "Gas detection unit",
            "Alarmlimits high [ppm] sensor1": "900 ppm",
            "Alarmlimits low [ppm] sensor1": "500 ppm",
            "China RoHS compliance": "Yes",
            "China RoHS exemption clause": "No",
            "Contains batteries": "No",
            "Division": "40",
            "EU RoHS compliance": "Yes",
            "EU RoHS exemption clause": "No",
            "Frequency [Hz]": "50/60 Hz",
            "Gas detecting sensor version": "Basic",
            "Packing format": "Multi pack",
            "Parts included": "Cable gland, Complete unit, Mounting kit, Calibration Certificate",
            "PFAS content [Yes/No]": "No",
            "Power consumption [A]": "0.25 A",
            "Quantity per packing format": "8 pc",
            "REACH Candidate List substances": "No",
            "Refrig. range [ppm] sensor1 [Max]": "1000 ppm",
            "Refrig. range [ppm] sensor1 [Min]": "0 ppm",
            "Refrigerants": "R717",
            "Relative humidity (RH) [%] [Max]": "90 %",
            "Relative humidity (RH) [%] [Min]": "15 %",
            "Response delay [s]": "0 s",
            "Sensor 1 type": "Semiconductor",
            "Supply voltage [V] AC [max]": "29 V",
            "Supply voltage [V] AC [min]": "19 V",
            "Supply voltage [V] DC [max]": "29 V",
            "Supply voltage [V] DC [min]": "19 V",
            "Temperature range [°C] [Max]": "50 °C",
            "Temperature range [°C] [Min]": "-40 °C",
            "Temperature range [°F] [Max]": "122 °F",
            "Temperature range [°F] [Min]": "-40 °F"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/1b/94/1b944375734745b23dc3d42bd97a4c694a052101ed715245de7a35ca36ebf346.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/1b/94/1b944375734745b23dc3d42bd97a4c694a052101ed715245de7a35ca36ebf346.jpg",
                "local_path": "danfoss/images/1b/94/1b944375734745b23dc3d42bd97a4c694a052101ed715245de7a35ca36ebf346.jpg",
                "original_url": "https://assets.danfoss.com/photos/142480/ID272156986407-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Gas detection in refrigeration systems",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c7/ca/c7ca338b0b528cf5f72ba1b92f0127134bb4d1c9f537fd428ddb5530c9f7e36d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c7/ca/c7ca338b0b528cf5f72ba1b92f0127134bb4d1c9f537fd428ddb5530c9f7e36d.pdf"
            },
            {
                "text": "Gas detection solution for industrial refrigeration",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/cb/eb/cbebdaed99ada3ff9c70c0597074ff41880f04cab667ddb5b2c596ff2e59d14a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/cb/eb/cbebdaed99ada3ff9c70c0597074ff41880f04cab667ddb5b2c596ff2e59d14a.pdf"
            },
            {
                "text": "Gas detection unit, Basic",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/0b/46/0b465cf3f5a926369e6a38271107a07d6b61ccd4d45d1a6bd733831939b39911.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/0b/46/0b465cf3f5a926369e6a38271107a07d6b61ccd4d45d1a6bd733831939b39911.pdf"
            },
            {
                "text": "Gas Detection Unit (GDU) - GDA, GDC, GDHC, GDHF, GDH",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ec/fe/ecfe7383cd2b7f84a2f0427a3957ea0ba5de7643383ed7c7cc99bd3b6c54abf1.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ec/fe/ecfe7383cd2b7f84a2f0427a3957ea0ba5de7643383ed7c7cc99bd3b6c54abf1.pdf"
            },
            {
                "text": "GD Troubleshooting Guide Level 1",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c8/9f/c89f89a08d30a13e5c99ad780af49d9dd6d9f8be8ee61548cbe17d56aff95938.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c8/9f/c89f89a08d30a13e5c99ad780af49d9dd6d9f8be8ee61548cbe17d56aff95938.pdf"
            },
            {
                "text": "Danfoss Gas Detection - Modbus communication",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f3/fe/f3fe2523a24a7c0ac9a3f61bee617d23fdceb559188224709b22d8ad821798f5.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f3/fe/f3fe2523a24a7c0ac9a3f61bee617d23fdceb559188224709b22d8ad821798f5.pdf"
            },
            {
                "text": "Danfoss Gas Detection Units - Type Basic, Premium and Heavy Duty - Direct display or Service Tool display operation",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/94/5a/945a5a685ab96370fbf76ce81712424e2c5dff6c90af3c4f24ef220530bc2255.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/94/5a/945a5a685ab96370fbf76ce81712424e2c5dff6c90af3c4f24ef220530bc2255.pdf"
            },
            {
                "text": "PC tool - Software for addressing, calibration and parameterization of Basic, Premium and Heavy Duty gas detection units and gas detection controller configuration",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3b/00/3b00b7b088779a180c6749ac8614167ae36e3034833534ea1999ae6fde7a8af9.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3b/00/3b00b7b088779a180c6749ac8614167ae36e3034833534ea1999ae6fde7a8af9.pdf"
            },
            {
                "text": "User guide - Danfoss Gas Detection - Controller unit and Expansion module",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/84/1d/841dd37dc7257e9f911f10dc32e6347de6ca62d96fc9dd19d4ad3b6c309b4346.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/84/1d/841dd37dc7257e9f911f10dc32e6347de6ca62d96fc9dd19d4ad3b6c309b4346.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5714279919813"
        },
        "description": "Gas detecting sensor version: Basic, Sensor 1 type: Semiconductor, Refrig. range [ppm] sensor1: 0 - 1000",
        "created_at": "2026-06-16 07:36:06",
        "variations": []
    }
}