    "data": {
        "id": 182831,
        "sku": "167G0115",
        "name": "IC7-30FA3N04-73A0E55F2+BAMT+BDBA+BEG1+BF20+CCXX+DAHR",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/167G0115",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 996,
            "name": "iC7-HVACR Frequency Converter"
        },
        "categories": [
            {
                "id": 996,
                "name": "iC7-HVACR Frequency Converter"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "35.56 Kilogram",
            "Net weight": "30.45 Kilogram",
            "Volume": "91.654 Liter",
            "EAN": "5715253996400",
            "Product series": "+DAHR, iC7-HVACR",
            "Product group": "IC7-30, iC7-30",
            "Product category": "FA, Frequency converter,air-cooled",
            "Product type": "3N, 3~",
            "Mains voltage": "04, 380-480 V AC",
            "Current rating": "-73A0, 73 A",
            "Power rating": "37K, 37 kW/50 hp",
            "Protection rating": "E55, IP55/UL Type 12",
            "EMC category": "F2, C2 category",
            "Cable entry and EMC plate": "+AAST, Standard plate",
            "Integrated brake chopper": "+ACXX, None",
            "Extra environmental protection": "+AGXX, None",
            "Humidity protection device": "+AHXX, None",
            "Integrated common-mode filter": "+AIXX, None",
            "Mains input device": "+AJXX, None",
            "DC terminals": "+ALXX, None",
            "Touch protection": "+AMXX, None",
            "Heat sink access panel": "+APXX, None",
            "Communication interface, X1/X2": "+BAMT, Modbus TCP OS7MT",
            "Communication interface, X0": "+BBEL, Ethernet port, no protocol",
            "Standard I/O": "+BDBA, 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO",
            "Functional safety": "+BEG1, STO int diagn., not upgradable",
            "Control panel": "+BF20, Control Panel 2.8 OPX20",
            "Interface board": "+BIXX, None",
            "Option slot A": "+CAX0, None",
            "Option slot B": "+CBXX, None, not upgradable",
            "Option slot C": "+CCXX, None, not upgradable",
            "Option slot D": "+CDX0, None",
            "Option Slot E": "+CEX0, None",
            "Customer specific application": "+DBXX, None",
            "Additional drive features 1": "+DD1X, None",
            "Additional drive features 2": "+DE2X, None",
            "Additional drive features 3": "+DF3X, None",
            "Additional drive features 4": "+DG4X, None",
            "Additional drive features 5": "+DH5X, None",
            "High speed enabled": "+DI6X, No",
            "Customization file package ID": "+EAXXXXXX, No customization",
            "Product software ID": "+ECXXX, Latest released version",
            "Technical documentation": "+EGIN, Installation guide",
            "Customer-specific label": "+EJXX, None",
            "Language package": "+EL01, Global",
            "Product specific marine cert.": "+VBXX, None",
            "Frame designation": "FB06, FB06",
            "Control Board type": "B5E, Standard Ethernet B5E",
            "Modelcode01": "IC7-30FA3N04-73A0E55F2",
            "Modelcode03": "+BAMT+BDBA",
            "Modelcode04": "+BEG1+BF20+CCXX",
            "Modelcode05": "+DAHR",
            "Input Voltage": "3x380-480V, 3x380-480V",
            "Input frequency": "50/60Hz, 50/60Hz",
            "Short circuit current rating": "100kA, 100kA",
            "Output frequency": "0-590Hz, 0-590Hz",
            "Typical motor power PL (110%)": "37kW(400V)/50HP(460V), 37kW(400V)/50HP(460V)",
            "Continous current IL (1/10min)": "73/66A, 73/66A",
            "Input current LO (1/10 min)": "69.7A/61.2A, 69.7A/61.2A",
            "Ambient temp LO (1/10 min)": "40°C/104°F, 40°C/104°F",
            "Typical motor power PH (150%)": "30KW(400V)/40HP(460V), 30KW(400V)/40HP(460V)",
            "Continous current IH (1/10min)": "61/55A, 61/55A",
            "Input current HO (1/10 min)": "56.9A/49.9A, 56.9A/49.9A",
            "Ambient temp HO (1/10 min)": "50°C/122°F, 50°C/122°F",
            "Efficiency class-Relative loss": "IE2 - 1.43%, IE2 - 1.43%",
            "Maximum Power Loss LO [W]": "761, 761",
            "Main unit Width": "216 mm / 8.5 in, 216 mm / 8.5 in",
            "Main unit Height": "672 mm / 26.5 in, 672 mm / 26.5 in",
            "Calculated Net Weight [kg]": "30.45",
            "Main unit Depth": "303 mm / 11.9 in, 303 mm / 11.9 in",
            "Calculated Gross Weight [kg]": "35.56",
            "ECCN EU": "Y901, Y901",
            "ECCN US": "3A999.a, 3A999.a",
            "Enclosure rating": "IP55 / TYPE 12, IP55 / TYPE 12",
            "Help Counter": "1",
            "High Speed Drive Warning": "NONE, NONE",
            "Product Catalog": "NO_VIEW, NO VIEW",
            "Product View (Switch)": "GLBL, Global (Standard)",
            "Recommended Plant": "ERR01, ERR01",
            "Typecode Part 1": "7FC-HRFA3N04-73A0E55F2",
            "Typecode Part 2": "-000184798",
            "Vendor": "ERR01, Cannot Determine Vendor"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/5f/80/5f8087236583204efef79e0139eb2aab486218518e305086c1890cc1e87cc48c.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/5f/80/5f8087236583204efef79e0139eb2aab486218518e305086c1890cc1e87cc48c.jpg",
                "local_path": "danfoss/images/5f/80/5f8087236583204efef79e0139eb2aab486218518e305086c1890cc1e87cc48c.jpg",
                "original_url": "https://assets.danfoss.com/drawings/241380/ID446230904242-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Connecting to iC7 Series Remotely via Mobile Network",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf"
            },
            {
                "text": "iC7 Series HVACR Application SW 2.0.0",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/9f/a4/9fa43c3a52927e0a021b89c6562afb97c04ca766726b4a5452b0ec742935f533.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/9f/a4/9fa43c3a52927e0a021b89c6562afb97c04ca766726b4a5452b0ec742935f533.pdf"
            },
            {
                "text": "MyDrive Insight for iC7; SW 2.20.0",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/cb/df/cbdf4cead8851e40f163ce441a65c9b72ec57a3242ca90c2cdd479fdb2b31220.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/cb/df/cbdf4cead8851e40f163ce441a65c9b72ec57a3242ca90c2cdd479fdb2b31220.pdf"
            },
            {
                "text": "MyDrive Insight Logic Feature",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1a/18/1a18521f1cb96543b892c1ba010f919c6b55d6d8fb7083d5818ad7ebfdddaa13.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1a/18/1a18521f1cb96543b892c1ba010f919c6b55d6d8fb7083d5818ad7ebfdddaa13.pdf"
            },
            {
                "text": "iC7-HVACR Selection Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/bf/52/bf5267e8588b8e259cf824ad92e9ed84688f8998d27640517bd2b703f0ddb424.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/bf/52/bf5267e8588b8e259cf824ad92e9ed84688f8998d27640517bd2b703f0ddb424.pdf"
            },
            {
                "text": "iC7-HVACR Frequency Converters",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ec/47/ec473adf82780dc423b02fd07f91604c5c84c89eee88d9e379f92350406b7a4e.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ec/47/ec473adf82780dc423b02fd07f91604c5c84c89eee88d9e379f92350406b7a4e.pdf"
            },
            {
                "text": "iC7 Series Control Panel",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf"
            },
            {
                "text": "iC7-Aqua and HVACR Frequency Converters, FA02–FA08/FB03–FB08/FK03–FK08 (1.3–170 A)",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a4/95/a4953e0cdf4cf4b29918b73b121858092483724b1e38d6c1ccb29e94ab794f9c.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a4/95/a4953e0cdf4cf4b29918b73b121858092483724b1e38d6c1ccb29e94ab794f9c.pdf"
            },
            {
                "text": "Functional Extension Options",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf"
            },
            {
                "text": "iC7 Series Modbus",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d3/78/d378e2937edcdc70be81fb8c5d52ace2967211688a935918db6dfbe1acc1dfb0.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d3/78/d378e2937edcdc70be81fb8c5d52ace2967211688a935918db6dfbe1acc1dfb0.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715253996400"
        },
        "description": "iC7-HVACR Frequency converter,air-cooled IC7-30FA3N04-73A0E55F2 +BAMT+BDBA+BEG1+BF20+CCXX +DAHR IP55/UL Type 12, Frame: FB06 3~, 380-480 V AC, 73 A EMC category: C2 category Control Panel 2.8 OPX20 Standard I/O: 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO Fieldbus protocols enabled: Modbus TCP OS7MT Other protocols enabled: Ethernet port, no protocol Functional Safety: STO int diagn., not upgradable Other options according to model code",
        "created_at": "2026-06-16 07:36:07",
        "variations": []
    }
}