        "id": 183200,
        "sku": "167G0606",
        "name": "IC7-30FA3N04-61A0E55F1+BAMR+BDBA+BEG1+BF20+CCXX+DAAQ",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/167G0606",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 937,
            "name": "iC7-Aqua Frequency Converter"
        },
        "categories": [
            {
                "id": 937,
                "name": "iC7-Aqua Frequency Converter"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "34.26 Kilogram",
            "Net weight": "29.15 Kilogram",
            "Volume": "91.654 Liter",
            "EAN": "5715786001381",
            "Product series": "+DAAQ, iC7-AQUA",
            "Product group": "IC7-30, iC7-30",
            "Product category": "FA, Frequency converter,air-cooled",
            "Product type": "3N, 3~",
            "Mains voltage": "04, 380-480 V AC",
            "Current rating": "-61A0, 61 A",
            "Power rating": "30K, 30 kW/40 hp",
            "Protection rating": "E55, IP55/UL Type 12",
            "EMC category": "F1, C1 and C2 category",
            "Cable entry and EMC plate": "+AAST, Standard plate",
            "Integrated brake chopper": "+ACXX, None",
            "Extra environmental protection": "+AGXX, None",
            "Humidity protection device": "+AHXX, None",
            "Integrated common-mode filter": "+AIXX, None",
            "Mains input device": "+AJXX, None",
            "DC terminals": "+ALXX, None",
            "Touch protection": "+AMXX, None",
            "Heat sink access panel": "+APXX, None",
            "Communication interface, X1/X2": "+BAMR, Modbus RTU OS7MR",
            "Communication interface, X0": "+BBEL, Ethernet port, no protocol",
            "Standard I/O": "+BDBA, 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO",
            "Functional safety": "+BEG1, STO int diagn., not upgradable",
            "Control panel": "+BF20, Control Panel 2.8 OPX20",
            "Interface board": "+BIXX, None",
            "Option slot A": "+CAX0, None",
            "Option slot B": "+CBXX, None, not upgradable",
            "Option slot C": "+CCXX, None, not upgradable",
            "Option slot D": "+CDX0, None",
            "Option Slot E": "+CEX0, None",
            "Customer specific application": "+DBXX, None",
            "Additional drive features 1": "+DD1X, None",
            "Additional drive features 2": "+DE2X, None",
            "Additional drive features 3": "+DF3X, None",
            "Additional drive features 4": "+DG4X, None",
            "Additional drive features 5": "+DH5X, None",
            "High speed enabled": "+DI6X, No",
            "Customization file package ID": "+EAXXXXXX, No customization",
            "Product software ID": "+ECXXX, Latest released version",
            "Technical documentation": "+EGIN, Installation guide",
            "Customer-specific label": "+EJXX, None",
            "Language package": "+EL01, Global",
            "Product specific marine cert.": "+VBXX, None",
            "Frame designation": "FB06, FB06",
            "Control Board type": "B5S, Standard Serial B5S",
            "Modelcode01": "IC7-30FA3N04-61A0E55F1",
            "Modelcode03": "+BAMR+BDBA",
            "Modelcode04": "+BEG1+BF20+CCXX",
            "Modelcode05": "+DAAQ",
            "Input Voltage": "3x380-480V, 3x380-480V",
            "Input frequency": "50/60Hz, 50/60Hz",
            "Short circuit current rating": "100kA, 100kA",
            "Output frequency": "0-590Hz, 0-590Hz",
            "Typical motor power PL (110%)": "30kW(400V)/40HP(460V), 30kW(400V)/40HP(460V)",
            "Continous current IL (1/10min)": "61/55A, 61/55A",
            "Input current LO (1/10 min)": "55.8A/49.4A, 55.8A/49.4A",
            "Ambient temp LO (1/10 min)": "40°C/104°F, 40°C/104°F",
            "Typical motor power PH (150%)": "22KW(400V)/30HP(460V), 22KW(400V)/30HP(460V)",
            "Continous current IH (1/10min)": "43/40A, 43/40A",
            "Input current HO (1/10 min)": "41.3A/36.5A, 41.3A/36.5A",
            "Ambient temp HO (1/10 min)": "50°C/122°F, 50°C/122°F",
            "Efficiency class-Relative loss": "IE2 - 1.37%, IE2 - 1.37%",
            "Maximum Power Loss LO [W]": "608, 608",
            "Main unit Width": "216 mm / 8.5 in, 216 mm / 8.5 in",
            "Main unit Height": "672 mm / 26.5 in, 672 mm / 26.5 in",
            "Main unit Depth": "303 mm / 11.9 in, 303 mm / 11.9 in",
            "Calculated Net Weight [kg]": "29.15",
            "Calculated Gross Weight [kg]": "34.26",
            "ECCN EU": "Y901, Y901",
            "ECCN US": "3A999.a, 3A999.a",
            "Enclosure rating": "IP55 / TYPE 12, IP55 / TYPE 12",
            "Help Counter": "1",
            "High Speed Drive Warning": "NONE, NONE",
            "Product Catalog": "NO_VIEW, NO VIEW",
            "Product View (Switch)": "GLBL, Global (Standard)",
            "Recommended Plant": "ERR01, ERR01",
            "Typecode Part 1": "7FC-AQFA3N04-61A0E55F1",
            "Typecode Part 2": "-000186886",
            "Vendor": "ERR01, Cannot Determine Vendor"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/5f/80/5f8087236583204efef79e0139eb2aab486218518e305086c1890cc1e87cc48c.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/5f/80/5f8087236583204efef79e0139eb2aab486218518e305086c1890cc1e87cc48c.jpg",
                "local_path": "danfoss/images/5f/80/5f8087236583204efef79e0139eb2aab486218518e305086c1890cc1e87cc48c.jpg",
                "original_url": "https://assets.danfoss.com/drawings/241380/ID446230904242-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Connecting to iC7 Series Remotely via Mobile Network",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf"
            },
            {
                "text": "iC7 Series Aqua Application SW 2.0.0",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/99/2c/992c3ae865fbefb4ba92e4f5f0e8262d4611fa0ada8e9f33d5fdb45e22a0f437.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/99/2c/992c3ae865fbefb4ba92e4f5f0e8262d4611fa0ada8e9f33d5fdb45e22a0f437.pdf"
            },
            {
                "text": "MyDrive Insight for iC7; SW 2.20.0",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/cb/df/cbdf4cead8851e40f163ce441a65c9b72ec57a3242ca90c2cdd479fdb2b31220.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/cb/df/cbdf4cead8851e40f163ce441a65c9b72ec57a3242ca90c2cdd479fdb2b31220.pdf"
            },
            {
                "text": "MyDrive Insight Logic Feature",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1a/18/1a18521f1cb96543b892c1ba010f919c6b55d6d8fb7083d5818ad7ebfdddaa13.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1a/18/1a18521f1cb96543b892c1ba010f919c6b55d6d8fb7083d5818ad7ebfdddaa13.pdf"
            },
            {
                "text": "iC7-Aqua Selection Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/2f/8e/2f8e4fce88f40b5df586c412508ef76a88b43a58585a79b87821f8b996320ddc.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/2f/8e/2f8e4fce88f40b5df586c412508ef76a88b43a58585a79b87821f8b996320ddc.pdf"
            },
            {
                "text": "iC7-Aqua Frequency Converters, 1.3-1260 A",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/77/18/771832d3ea3f8bf145c75ba2814a17c12b27bdebb2154436c975e312e466cac5.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/77/18/771832d3ea3f8bf145c75ba2814a17c12b27bdebb2154436c975e312e466cac5.pdf"
            },
            {
                "text": "iC7 Series Control Panel",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c5/bc/c5bc307f4abb3b0c124f76d56038366d8eb3a6bdd1920f21b7f7f0a6c5799d0d.pdf"
            },
            {
                "text": "iC7-Aqua and HVACR Frequency Converters, FA02–FA08/FB03–FB08/FK03–FK08 (1.3–170 A)",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a4/95/a4953e0cdf4cf4b29918b73b121858092483724b1e38d6c1ccb29e94ab794f9c.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a4/95/a4953e0cdf4cf4b29918b73b121858092483724b1e38d6c1ccb29e94ab794f9c.pdf"
            },
            {
                "text": "Functional Extension Options",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ac/52/ac520d0d2a69751541db1863df5e0b475e7ed790af166129643728dd3550b8f3.pdf"
            },
            {
                "text": "iC7 Series Modbus RTU",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/46/51/46513fbdefc9265c3d877ef56502395752abf0defab0d564d3e1bcf1e3c11f94.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/46/51/46513fbdefc9265c3d877ef56502395752abf0defab0d564d3e1bcf1e3c11f94.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715786001381"
        },
        "description": "iC7-AQUA Frequency converter,air-cooled IC7-30FA3N04-61A0E55F1 +BAMR+BDBA+BEG1+BF20+CCXX +DAAQ IP55/UL Type 12, Frame: FB06 3~, 380-480 V AC, 61 A EMC category: C1 and C2 category Cable Entry: Standard plate Mains Input: None Control Panel: Control Panel 2.8 OPX20 Standard I/O: 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO Fieldbus protocols enabled: Modbus RTU OS7MR Other protocols enabled: Ethernet port, no protocol Functional Safety: STO int diagn., not upgradable Other options according to model code",
        "created_at": "2026-06-16 07:36:07",
        "variations": []
    }
}