{
    "data": {
        "id": 197780,
        "sku": "180B0066",
        "name": "PAH pumps, PAH 80 CCW",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/180B0066",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 1010,
            "name": "PAH"
        },
        "categories": [
            {
                "id": 1010,
                "name": "PAH"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "36.417 Kilogram",
            "Net weight": "30.3 Kilogram",
            "Volume": "34.2 Liter",
            "EAN": "5715162667187",
            "Type": "PAH 50-100",
            "Product group": "Pump",
            "Ambient temperature [°C] [Max]": "50 °C",
            "Ambient temperature [°C] [Min]": "0 °C",
            "Ambient temperature [°F] [Max]": "122 °F",
            "Ambient temperature [°F] [Min]": "32 °F",
            "Approval": "CE",
            "ATEX compliance": "No",
            "Body material": "AISI 304",
            "CE evaluated": "Yes",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Country of origin": "Denmark",
            "Description": "PAH 80",
            "Direction": "CCW",
            "Displacement [cm³/rev]": "80 cm³/rev",
            "Displacement [in³/rev]": "4.88 in³/rev",
            "Drain connection size [in]": "1/4 in",
            "Drain connection standard": "BSPP",
            "Drain connection type": "Thread",
            "EU RoHS compliance": "Out of scope",
            "Flow [gpm] [Max]": "35.9 gal/min",
            "Flow [gpm] [Min]": "12.9 gal/min",
            "Flow [l/min] [Max]": "138.1 l/min",
            "Flow [l/min] [Min]": "49.7 l/min",
            "In scope of WEEE": "No",
            "Inlet connection size [in]": "1 1/2 in",
            "Inlet connection standard": "BSPP",
            "Inlet connection type": "Thread",
            "Inlet pressure [barg] [Max]": "4 barg",
            "Inlet pressure [barg] [Min]": "0 barg",
            "Inlet pressure [psig] [Max]": "58 psig",
            "Inlet pressure [psig] [Min]": "0 psig",
            "Media temperature [°C] [Max]": "50 °C",
            "Media temperature [°C] [Min]": "2 °C",
            "Media temperature [°F] [Max]": "122 °F",
            "Media temperature [°F] [Min]": "36 °F",
            "Outlet connection size [in]": "1 1/4 in",
            "Outlet connection standard": "BSPP",
            "Outlet connection type": "Thread",
            "Outlet pressure [barg] [Max]": "160 barg",
            "Outlet pressure [barg] [Min]": "30 barg",
            "Outlet pressure [psig] [Max]": "2320 psig",
            "Outlet pressure [psig] [Min]": "435 psig",
            "Outside dimensions of packaging LxWxH [in]": "14,9x11,8x11,8",
            "Outside dimensions of packaging LxWxH [mm]": "380x300x300",
            "Product description": "PAH pumps",
            "REACH Candidate List substances": "No",
            "Seal Material": "NBR",
            "Serviceable": "Yes",
            "Sound pressure level [dB(A)]": "80 dBA",
            "Speed [rpm] [Max]": "1800 rpm",
            "Speed [rpm] [Min]": "700 rpm",
            "Speed continuous [rpm] [Min]": "700 rpm",
            "Type designation": "PAH 80 CCW",
            "UL evaluated": "No"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/0f/dc/0fdc8d21fdb897a7df34bb283509a7f779d8a48ed5ed6f8ca6d7387253c9af69.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/0f/dc/0fdc8d21fdb897a7df34bb283509a7f779d8a48ed5ed6f8ca6d7387253c9af69.jpg",
                "local_path": "danfoss/images/0f/dc/0fdc8d21fdb897a7df34bb283509a7f779d8a48ed5ed6f8ca6d7387253c9af69.jpg",
                "original_url": "https://assets.danfoss.com/photos/145994/ID136733136392-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Compact Danfoss PAH pumps protect priceless Chinese cultural heritage from fire",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/9b/76/9b76e166e645bd9576343cfe430286c8609798869ca63ab9321db76d5dd3306a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/9b/76/9b76e166e645bd9576343cfe430286c8609798869ca63ab9321db76d5dd3306a.pdf"
            },
            {
                "text": "Moscow office complex saves 180 m2 with compact fire suppression system powered by Danfoss PAH pumps",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a3/6c/a36c4f4228ee265ad5fb14f9602e0dc0b936b2b6a1201c6b427c12f00f419da7.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a3/6c/a36c4f4228ee265ad5fb14f9602e0dc0b936b2b6a1201c6b427c12f00f419da7.pdf"
            },
            {
                "text": "Sawmill MD engineers profitable humidity treatment with flexible Danfoss PAH pumps",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/14/2a/142a5f4c1b15aa1c643bab15535f389f446e8935283dc172101b2bdca27c6f29.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/14/2a/142a5f4c1b15aa1c643bab15535f389f446e8935283dc172101b2bdca27c6f29.pdf"
            },
            {
                "text": "Data sheet PAH pumps",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/7d/22/7d222af118cc346de75db05c498e78177ff742be95aeb3f247b417e692e15441.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/7d/22/7d222af118cc346de75db05c498e78177ff742be95aeb3f247b417e692e15441.pdf"
            },
            {
                "text": "PAH 20-100 Instructions",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/e2/82/e282f9d106ac1b1b81cd30e511c470bd57dc0b25d747d78b6bcd4ab8f45fb44b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/e2/82/e282f9d106ac1b1b81cd30e511c470bd57dc0b25d747d78b6bcd4ab8f45fb44b.pdf"
            },
            {
                "text": "PAH 20-100 Installation, Opearation and Maintenance manual",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/89/1a/891a0039b51d171e02f81ff7877ba655f4485c657a27a099c769cea43f2d8004.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/89/1a/891a0039b51d171e02f81ff7877ba655f4485c657a27a099c769cea43f2d8004.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715162667187"
        },
        "description": "Flow [gpm] [Max]: 35.9, Flow [l/min] [Max]: 138.1, Outlet pressure [barg] [Max]: 160, Outlet pressure [psig] [Max]: 2320, Speed [rpm] [Max]: 1800, Speed continuous [rpm] [Min]: 700",
        "created_at": "2026-06-16 07:36:10",
        "variations": []
    }
}