{
    "data": {
        "id": 197820,
        "sku": "180B3008",
        "name": "APP pumps, APP 8.2",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/180B3008",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 1020,
            "name": "APP 0.6-46 pumps"
        },
        "categories": [
            {
                "id": 1020,
                "name": "APP 0.6-46 pumps"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "36.058 Kilogram",
            "Net weight": "33.969 Kilogram",
            "Volume": "34.073 Liter",
            "EAN": "5715162667682",
            "Type": "APP 5.1-10.2",
            "Product group": "Pump",
            "Ambient temperature [°C] [Max]": "50 °C",
            "Ambient temperature [°C] [Min]": "0 °C",
            "Ambient temperature [°F] [Max]": "122 °F",
            "Ambient temperature [°F] [Min]": "32 °F",
            "Approval": "CE",
            "ATEX compliance": "No",
            "Body material": "Duplex",
            "CE evaluated": "Yes",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Country of origin": "Denmark",
            "Description": "Pump for sea- or brackish water",
            "Displacement [cm³/rev]": "80.4 cm³/rev",
            "Displacement [in³/rev]": "4.91 in³/rev",
            "Drain connection size (metric)": "M6",
            "Drain connection standard": "Metric",
            "Drain connection type": "Thread",
            "EU RoHS compliance": "Out of scope",
            "Flow [gpm] [Max]": "36 gal/min",
            "Flow [gpm] [Min]": "13 gal/min",
            "Flow [l/min] [Max]": "138.5 l/min",
            "Flow [l/min] [Min]": "50 l/min",
            "Flow [m³/h] [Max]": "8.3 m³/h",
            "Flow [m³/h] [Min]": "3 m³/h",
            "In scope of WEEE": "No",
            "Inlet connection size (metric)": "M42",
            "Inlet connection standard": "Metric",
            "Inlet connection type": "Thread",
            "Inlet pressure [barg] [Max]": "5 barg",
            "Inlet pressure [barg] [Min]": "0.5 barg",
            "Inlet pressure [psig] [Max]": "72.5 psig",
            "Inlet pressure [psig] [Min]": "7.3 psig",
            "Inlet pressure peak [barg] [Max]": "5 barg",
            "Inlet pressure peak [psig] [Max]": "73 psig",
            "Media temperature [°C] [Max]": "50 °C",
            "Media temperature [°C] [Min]": "2 °C",
            "Media temperature [°F] [Max]": "122 °F",
            "Media temperature [°F] [Min]": "36 °F",
            "Outlet connection size (metric)": "M42",
            "Outlet connection standard": "Metric",
            "Outlet connection type": "Thread",
            "Outlet pressure [barg] [Max]": "83 barg",
            "Outlet pressure [barg] [Min]": "20 barg",
            "Outlet pressure [psig] [Max]": "1200 psig",
            "Outlet pressure [psig] [Min]": "290 psig",
            "Outside dimensions of packaging LxWxH [in]": "14,9x11,8x11,8",
            "Outside dimensions of packaging LxWxH [mm]": "380x300x300",
            "Product description": "APP pumps",
            "REACH Candidate List substances": "No",
            "Seal Material": "NBR",
            "Serviceable": "Yes",
            "Sound pressure level [dB(A)]": "78 dBA",
            "Speed [rpm] [Max]": "1800 rpm",
            "Speed [rpm] [Min]": "700 rpm",
            "Speed continuous [rpm] [Min]": "700 rpm",
            "Type designation": "APP 8.2",
            "UL evaluated": "No"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/fa/03/fa034aca691b17b3e1b96239f57fde3348b165ac72f4dbd7802d901cca66d6ff.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/fa/03/fa034aca691b17b3e1b96239f57fde3348b165ac72f4dbd7802d901cca66d6ff.jpg",
                "local_path": "danfoss/images/fa/03/fa034aca691b17b3e1b96239f57fde3348b165ac72f4dbd7802d901cca66d6ff.jpg",
                "original_url": "https://assets.danfoss.com/photos/353406/ID136437534350-0102.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Salt Separation Services selects the compact and highly reliable Danfoss pump for the Royal Navy´s aircraft carriers",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/22/5c/225c5e5cf037dfd549c585e1b8dfc2b05175f786ca33e06a1dafd0ba53367fd9.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/22/5c/225c5e5cf037dfd549c585e1b8dfc2b05175f786ca33e06a1dafd0ba53367fd9.pdf"
            },
            {
                "text": "TDR relies on efficient Danfoss APP pumps for profitability at ZLD wastewater treatment facility",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ef/69/ef69b2ec0c3b1d9a1610ad268a717fcaa2e0a3103a98c9a46aff721dba84c6ed.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ef/69/ef69b2ec0c3b1d9a1610ad268a717fcaa2e0a3103a98c9a46aff721dba84c6ed.pdf"
            },
            {
                "text": "TSG chooses only Danfoss pumps and drives - because operating margins matter",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3c/bf/3cbf25d2118b7c265fb911b2c063c8451be6c40bfe758f69de04cce0fc4ba43a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3c/bf/3cbf25d2118b7c265fb911b2c063c8451be6c40bfe758f69de04cce0fc4ba43a.pdf"
            },
            {
                "text": "APP 0.6-46 pumps data sheet",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a6/38/a638bf8ac4739904f15d49b00e1ca9cb8d54391b126bde6f08b7eca27a5c7712.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a6/38/a638bf8ac4739904f15d49b00e1ca9cb8d54391b126bde6f08b7eca27a5c7712.pdf"
            },
            {
                "text": "APP and iSave overload protection",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/51/f2/51f2ad073f40fb37a33aba2a009ba8f6c5e4e7e815e509a6314cd90f3099f999.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/51/f2/51f2ad073f40fb37a33aba2a009ba8f6c5e4e7e815e509a6314cd90f3099f999.pdf"
            },
            {
                "text": "Parallel coupled APP pumps and iSave energy recovery device",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/78/a3/78a3d3ace8ceb0c97cbfd6c17fe560e1b7ce643b5cf08fa04bfe83a8f5a95105.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/78/a3/78a3d3ace8ceb0c97cbfd6c17fe560e1b7ce643b5cf08fa04bfe83a8f5a95105.pdf"
            },
            {
                "text": "Piping connections",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/2d/a5/2da5c7c0c12b113bec9e6697725f4d07a325775f0762b89d497869ce60eda2ee.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/2d/a5/2da5c7c0c12b113bec9e6697725f4d07a325775f0762b89d497869ce60eda2ee.pdf"
            },
            {
                "text": "Pressure Safety Valve in a seawater RO system",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d1/75/d175db242f1a94ecf2fa315df0f7b7b7ad309d4a4241ef52d956ffc69ad330f8.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d1/75/d175db242f1a94ecf2fa315df0f7b7b7ad309d4a4241ef52d956ffc69ad330f8.pdf"
            },
            {
                "text": "APP (W) 5.1-10.2",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f0/ed/f0edae0b29da3bce5e478fcefacb4d6e047a99f8a7833131c2e23b0b6423a81a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f0/ed/f0edae0b29da3bce5e478fcefacb4d6e047a99f8a7833131c2e23b0b6423a81a.pdf"
            },
            {
                "text": "APP ((W) 5.1-10.2",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/53/62/5362634c7ae2bb432254d22e9b3ccf2c336b3fdb821f530980974f5c80193e63.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/53/62/5362634c7ae2bb432254d22e9b3ccf2c336b3fdb821f530980974f5c80193e63.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715162667682"
        },
        "description": "Flow [gpm] [Max]: 36, Flow [l/min] [Max]: 138.5, Outlet pressure [barg] [Max]: 83, Outlet pressure [psig] [Max]: 1200, Speed [rpm] [Max]: 1800, Speed [rpm] [Min]: 700",
        "created_at": "2026-06-16 07:36:10",
        "variations": []
    }
}