    "data": {
        "id": 198148,
        "sku": "180B6108",
        "name": "PAH pumps, PAH 10 Ex",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/180B6108",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 1010,
            "name": "PAH"
        },
        "categories": [
            {
                "id": 1010,
                "name": "PAH"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "8.355 Kilogram",
            "Net weight": "7.7 Kilogram",
            "Volume": "5.968 Liter",
            "EAN": "5715162670972",
            "Type": "PAH 10-12.5",
            "Product group": "Pump",
            "Ambient temperature [°C] [Max]": "50 °C",
            "Ambient temperature [°C] [Min]": "0 °C",
            "Ambient temperature [°F] [Max]": "122 °F",
            "Ambient temperature [°F] [Min]": "32 °F",
            "Approval": "CE, ATEX",
            "ATEX compliance": "Ex II 2G cb T6 / Ex II 3G c T6",
            "Body material": "AISI 304",
            "CE evaluated": "Yes",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Country of origin": "Denmark",
            "Description": "PAH 10 Ex",
            "Displacement [cm³/rev]": "12.5 cm³/rev",
            "Displacement [in³/rev]": "0.76 in³/rev",
            "Drain connection size [in]": "1/4 in",
            "Drain connection standard": "BSPP",
            "Drain connection type": "Thread",
            "EU RoHS compliance": "Out of scope",
            "Flow [gpm] [Max]": "6.7 gal/min",
            "Flow [gpm] [Min]": "2.6 gal/min",
            "Flow [l/min] [Max]": "27.7 l/min",
            "Flow [l/min] [Min]": "10.2 l/min",
            "In scope of WEEE": "No",
            "Inlet connection size [in]": "3/4 in",
            "Inlet connection standard": "BSPP",
            "Inlet connection type": "Thread",
            "Inlet pressure [barg] [Max]": "4 barg",
            "Inlet pressure [barg] [Min]": "0 barg",
            "Inlet pressure [psig] [Max]": "58 psig",
            "Inlet pressure [psig] [Min]": "0 psig",
            "Inlet pressure peak [barg] [Max]": "4 barg",
            "Inlet pressure peak [psig] [Max]": "58 psig",
            "Media temperature [°C] [Max]": "50 °C",
            "Media temperature [°C] [Min]": "2 °C",
            "Media temperature [°F] [Max]": "122 °F",
            "Media temperature [°F] [Min]": "36 °F",
            "Outlet connection size [in]": "3/8 in",
            "Outlet connection standard": "BSPP",
            "Outlet connection type": "Thread",
            "Outlet pressure [barg] [Max]": "140 barg",
            "Outlet pressure [barg] [Min]": "10 barg",
            "Outlet pressure [psig] [Max]": "2030 psig",
            "Outlet pressure [psig] [Min]": "145 psig",
            "Outside dimensions of packaging LxWxH [in]": "10,7x5,9x5,4",
            "Outside dimensions of packaging LxWxH [mm]": "274x151x137",
            "Product description": "PAH pumps",
            "REACH Candidate List substances": "No",
            "Seal Material": "NBR",
            "Serviceable": "Yes",
            "Sound pressure level [dB(A)]": "75 dBA",
            "Speed [rpm] [Max]": "2400 rpm",
            "Speed [rpm] [Min]": "1000 rpm",
            "Speed continuous [rpm] [Min]": "1000 rpm",
            "Type designation": "PAH 10 Ex",
            "UL evaluated": "No"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/13/e1/13e1a34d3d02fa65fb499d6dde0bc0dab602f2c0fff3002ade3786f33b9a2458.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/13/e1/13e1a34d3d02fa65fb499d6dde0bc0dab602f2c0fff3002ade3786f33b9a2458.jpg",
                "local_path": "danfoss/images/13/e1/13e1a34d3d02fa65fb499d6dde0bc0dab602f2c0fff3002ade3786f33b9a2458.jpg",
                "original_url": "https://assets.danfoss.com/photos/108609/ID136728370379-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Finnish sawmill doubles humidification capacity with the same Danfoss PAH pump - and minimal investment",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d1/1e/d11ef8e7ea9eeca07d1e03c7c47c812a863d4a2b14a5ee4f9949be4a69f394a9.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d1/1e/d11ef8e7ea9eeca07d1e03c7c47c812a863d4a2b14a5ee4f9949be4a69f394a9.pdf"
            },
            {
                "text": "Data sheet PAH pumps",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/7d/22/7d222af118cc346de75db05c498e78177ff742be95aeb3f247b417e692e15441.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/7d/22/7d222af118cc346de75db05c498e78177ff742be95aeb3f247b417e692e15441.pdf"
            },
            {
                "text": "ATEX instruction for APP 0.6-10.2 Ex / PAH 2-100 Ex / PAHT C 2-6.3 Ex / PAHT G 2-308 Ex",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/80/f3/80f39da720d4b96540ced13dbeebc0e600ed64f1ee5824be42c5966762a02a1d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/80/f3/80f39da720d4b96540ced13dbeebc0e600ed64f1ee5824be42c5966762a02a1d.pdf"
            },
            {
                "text": "PAH/PAHT 2-12.5 Instruction",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/bc/f7/bcf707d453c275b84c667b8967f9bf50f729e8cb8e8bcea75240548bfbe37bf4.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/bc/f7/bcf707d453c275b84c667b8967f9bf50f729e8cb8e8bcea75240548bfbe37bf4.pdf"
            },
            {
                "text": "PAH 2-12.5 Installation, Opearation and Maintenance manual",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/24/2d/242d3ad4cb60c320ea783853a45678ab0915d28770b2653680d058931d20b3c8.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/24/2d/242d3ad4cb60c320ea783853a45678ab0915d28770b2653680d058931d20b3c8.pdf"
            },
            {
                "text": "PAH/PAHT/PAHT G 10-12.5 Disassembling and assembling",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/7b/5a/7b5a457fcc3c813bed2b3946d0a1a8cf339ad1d571a0a1c93542d47c916c72ef.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/7b/5a/7b5a457fcc3c813bed2b3946d0a1a8cf339ad1d571a0a1c93542d47c916c72ef.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715162670972"
        },
        "description": "Flow [gpm] [Max]: 6.7, Flow [l/min] [Max]: 27.7, Outlet pressure [barg] [Max]: 140, Outlet pressure [psig] [Max]: 2030, Speed [rpm] [Max]: 2400, Speed continuous [rpm] [Min]: 1000, ATEX compliance: Ex II 2G cb T6 / Ex II 3G c T6",
        "created_at": "2026-06-16 07:36:10",
        "variations": []
    }
}