    "data": {
        "id": 198166,
        "sku": "180B6185",
        "name": "PAHT G pumps, PAHT G 50 Ex",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/180B6185",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 1014,
            "name": "PAHT G 2-308"
        },
        "categories": [
            {
                "id": 1014,
                "name": "PAHT G 2-308"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "43 Kilogram",
            "Net weight": "35.5 Kilogram",
            "Volume": "34.2 Liter",
            "EAN": "5715162671269",
            "Type": "PAHT G 50-90",
            "Product group": "Pump",
            "Ambient temperature [°C] [Max]": "50 °C",
            "Ambient temperature [°C] [Min]": "0 °C",
            "Ambient temperature [°F] [Max]": "122 °F",
            "Ambient temperature [°F] [Min]": "32 °F",
            "Approval": "CE, ATEX",
            "ATEX compliance": "Ex II 2G cb T6 / Ex II 3G c T6",
            "Body material": "AISI 316",
            "CE evaluated": "Yes",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Country of origin": "Denmark",
            "Description": "PAHT G 50 Ex",
            "Displacement [cm³/rev]": "50 cm³/rev",
            "Displacement [in³/rev]": "3.05 in³/rev",
            "Drain connection size (metric)": "M6",
            "Drain connection standard": "Metric",
            "Drain connection type": "Thread",
            "EU RoHS compliance": "Out of scope",
            "Flow [gpm] [Max]": "21.7 gal/min",
            "Flow [gpm] [Min]": "7.4 gal/min",
            "Flow [l/min] [Max]": "83.7 l/min",
            "Flow [l/min] [Min]": "28.6 l/min",
            "In scope of WEEE": "No",
            "Inlet connection size [in]": "1 1/2 in",
            "Inlet connection standard": "BSPP",
            "Inlet connection type": "Thread",
            "Inlet pressure [barg] [Max]": "6 barg",
            "Inlet pressure [barg] [Min]": "0 barg",
            "Inlet pressure [psig] [Max]": "87 psig",
            "Inlet pressure [psig] [Min]": "0 psig",
            "Inlet pressure peak [barg] [Max]": "20 barg",
            "Inlet pressure peak [psig] [Max]": "290 psig",
            "Media temperature [°C] [Max]": "50 °C",
            "Media temperature [°C] [Min]": "2 °C",
            "Media temperature [°F] [Max]": "122 °F",
            "Media temperature [°F] [Min]": "36 °F",
            "Outlet connection size [in]": "1 in",
            "Outlet connection standard": "BSPP",
            "Outlet connection type": "Thread",
            "Outlet pressure [barg] [Max]": "80 barg",
            "Outlet pressure [barg] [Min]": "30 barg",
            "Outlet pressure [psig] [Max]": "1160 psig",
            "Outlet pressure [psig] [Min]": "435 psig",
            "Outside dimensions of packaging LxWxH [in]": "14,9x11,8x11,8",
            "Outside dimensions of packaging LxWxH [mm]": "380x300x300",
            "Product description": "PAHT G pumps",
            "REACH Candidate List substances": "No",
            "Seal Material": "NBR",
            "Serviceable": "Spare parts PAHT G 50/63/70/80/90",
            "Sound pressure level [dB(A)]": "81 dBA",
            "Speed [rpm] [Max]": "1800 rpm",
            "Speed [rpm] [Min]": "700 rpm",
            "Speed continuous [rpm] [Min]": "1000 rpm",
            "Type designation": "PAHT G 50 Ex",
            "UL evaluated": "No"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/71/56/7156f1d4a6ee7e6ba89ea40d9270201076e0d911b02ec5530807590a845fa585.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/71/56/7156f1d4a6ee7e6ba89ea40d9270201076e0d911b02ec5530807590a845fa585.jpg",
                "local_path": "danfoss/images/71/56/7156f1d4a6ee7e6ba89ea40d9270201076e0d911b02ec5530807590a845fa585.jpg",
                "original_url": "https://assets.danfoss.com/photos/127195/ID136741552418-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Pump, PAHT G 2-308",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f8/bb/f8bba56b326a8370cd27fb102a6dc2f1e32b0396e95fcb96321cc4a74ed09482.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f8/bb/f8bba56b326a8370cd27fb102a6dc2f1e32b0396e95fcb96321cc4a74ed09482.pdf"
            },
            {
                "text": "ATEX instruction for APP 0.6-10.2 Ex / PAH 2-100 Ex / PAHT C 2-6.3 Ex / PAHT G 2-308 Ex",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/80/f3/80f39da720d4b96540ced13dbeebc0e600ed64f1ee5824be42c5966762a02a1d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/80/f3/80f39da720d4b96540ced13dbeebc0e600ed64f1ee5824be42c5966762a02a1d.pdf"
            },
            {
                "text": "PAHT G 2-308 Ex in dust and gas applications Instruction",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f9/c9/f9c97fb4abec6e22f21babc6cd03742d8d6d3172c2fc8ec7b83f906aa817a5af.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f9/c9/f9c97fb4abec6e22f21babc6cd03742d8d6d3172c2fc8ec7b83f906aa817a5af.pdf"
            },
            {
                "text": "PAHT G 20-32 and PAHT G 50-90 Instruction",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a8/f3/a8f368b4df27bfedefcbb1659e9c6a56c590e3010e3fcdd7c42d8824972dfc45.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a8/f3/a8f368b4df27bfedefcbb1659e9c6a56c590e3010e3fcdd7c42d8824972dfc45.pdf"
            },
            {
                "text": "PAHT G 20-90 Installation, Opearation and Maintenance manual",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/65/c4/65c43005cecd1f6a3725fa26199a3528f5d31b39192e481400321620e87a624f.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/65/c4/65c43005cecd1f6a3725fa26199a3528f5d31b39192e481400321620e87a624f.pdf"
            },
            {
                "text": "PAHT and PAHT G 50-90 Disassembling and assembling",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/e4/80/e48011a74484a4df343ebe7a37acb5d1a2076d85c2bb866fa76932726c3bd9f2.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/e4/80/e48011a74484a4df343ebe7a37acb5d1a2076d85c2bb866fa76932726c3bd9f2.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715162671269"
        },
        "description": "Flow [gpm] [Max]: 21.7, Flow [l/min] [Max]: 83.7, Outlet pressure [barg] [Max]: 80, Outlet pressure [psig] [Max]: 1160, Speed [rpm] [Max]: 1800, Speed continuous [rpm] [Min]: 1000, ATEX compliance: Ex II 2G cb T6 / Ex II 3G c T6",
        "created_at": "2026-06-16 07:36:10",
        "variations": []
    }
}