    "data": {
        "id": 198259,
        "sku": "180F7011",
        "name": "Energy Recovery Device, ISAVE 40",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/180F7011",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 1042,
            "name": "iSave 21 Plus / iSave 40"
        },
        "categories": [
            {
                "id": 1042,
                "name": "iSave 21 Plus / iSave 40"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "149.2 Kilogram",
            "Net weight": "146.86 Kilogram",
            "Volume": "139.101 Liter",
            "EAN": "5715162672280",
            "Type": "iSave 40",
            "Product group": "Energy Recovery Device",
            "Allowable working torque [lbf·ft] [Max]": "75 lbf∙ft",
            "Allowable working torque [Nm] [Max]": "102 N-m",
            "Ambient temperature [°C] [Max]": "50 °C",
            "Ambient temperature [°C] [Min]": "0 °C",
            "Ambient temperature [°F] [Max]": "122 °F",
            "Ambient temperature [°F] [Min]": "32 °F",
            "Approval": "CE",
            "CE evaluated": "Yes",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Country of origin": "Denmark",
            "Description": "iSave without motor",
            "Differential pressure HP in out [barg] [Max]": "5 barg",
            "Differential pressure HP in out [psig] [Max]": "72 psig",
            "Drain connection size [in]": "1/4 in",
            "Drain connection standard": "BSPP",
            "Drain connection type": "BSPP",
            "EU RoHS compliance": "Yes",
            "EU RoHS exemption clause": "No",
            "Flow [gpm] [Min]": "92 gal/min",
            "Flow [m³/h] [Min]": "21 m³/h",
            "HP inlet connection size [in]": "3 in",
            "HP Inlet connection standard": "Victaulic",
            "HP inlet pressure [barg] [Max]": "83 barg",
            "HP inlet pressure [barg] [Min]": "20 barg",
            "HP inlet pressure [psig] [Max]": "1200 psig",
            "HP inlet pressure [psig] [Min]": "290 psig",
            "HP inlet pressure, intermittent [barg] [Min]": "3 barg",
            "HP inlet pressure, intermittent [psig] [Min]": "44 psig",
            "HP out flow [gpm] [Max]": "181 gal/min",
            "HP out flow [m³/h] [Max]": "41 m³/h",
            "HP outlet connection size [in]": "3 in",
            "HP Outlet connection standard": "Victaulic",
            "HP outlet pressure [barg] [Max]": "83 barg",
            "HP outlet pressure [psig] [Max]": "1200 psig",
            "In scope of WEEE": "No",
            "LP in out @ max flow [psig]": "18 psig",
            "LP in out @ max. flow [barg]": "1 barg",
            "LP inlet allowable working flow [gpm] [Max]": "295 gal/min",
            "LP inlet allowable working flow [m³/h] [Max]": "67 m³/h",
            "LP inlet connection size [in]": "3 in",
            "LP Inlet connection standard": "Victaulic",
            "LP inlet pressure [barg] [Max]": "5 barg",
            "LP inlet pressure [psig] [Max]": "72 psig",
            "LP Inlet pressure peak [barg]": "10 barg",
            "LP Inlet pressure peak [psig]": "145 psig",
            "LP outlet connection size [in]": "3 in",
            "LP outlet pressure [barg] [Min]": "1 barg",
            "LP outlet pressure [psig] [Min]": "15 psig",
            "Lubrication flow at 60 [m³/h] [Max]": "0.8 m³/h",
            "Lubrication flow at 871 [gpm] [Max]": "3.5 gal/min",
            "Material type": "Duplex, Super Duplex",
            "Media temperature [°C] [Max]": "40 °C",
            "Media temperature [°C] [Min]": "2 °C",
            "Media temperature [°F] [Max]": "104 °F",
            "Media temperature [°F] [Min]": "36 °F",
            "Mounting orientation": "Horizontal, Vertical, Bare shafted",
            "Outside dimensions of packaging LxWxH [in]": "29,8x14,9x14,9",
            "Outside dimensions of packaging LxWxH [mm]": "760x380x380",
            "Product description": "iSave",
            "Rated power [HP]": "0 HP",
            "REACH Candidate List substances": "No",
            "Seal Material": "NBR",
            "Serviceable": "Yes",
            "Sound pressure level [dB(A)]": "84 dBA",
            "Speed [rpm] [Max]": "1200 rpm",
            "Speed [rpm] [Min]": "600 rpm",
            "Starting torque [lbf·ft] [Max]": "110 lbf∙ft",
            "Starting torque [Nm] [Max]": "150 N-m",
            "Type designation": "ISAVE 40",
            "UL evaluated": "No"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/18/9d/189d94cf51d735ff5cb332aa7b9cde8e244a46653c2ffe661ab0aef40f5f4142.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/18/9d/189d94cf51d735ff5cb332aa7b9cde8e244a46653c2ffe661ab0aef40f5f4142.jpg",
                "local_path": "danfoss/images/18/9d/189d94cf51d735ff5cb332aa7b9cde8e244a46653c2ffe661ab0aef40f5f4142.jpg",
                "original_url": "https://assets.danfoss.com/drawings/219540/ID435832225135-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Danfoss iSave® ERDs at the heart of new, high-end containerized SWRO units",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a2/0c/a20c2c229b987ea67350380038517978bf04d34c1be7f932b9cdb127c46fb441.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a2/0c/a20c2c229b987ea67350380038517978bf04d34c1be7f932b9cdb127c46fb441.pdf"
            },
            {
                "text": "Krosys saves energy and maintenance costs while processing unique “lava water”",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3c/a6/3ca6649234592dd60cb40f7751d8c0a87e52830d1882a7558b276070d6bebc14.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3c/a6/3ca6649234592dd60cb40f7751d8c0a87e52830d1882a7558b276070d6bebc14.pdf"
            },
            {
                "text": "Low energy and maintenance costskey to success at plant in Bermuda",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/b0/f5/b0f5a259be992c863c641739441fea88e0f79742167f2db1f32b4ddbcac80c58.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/b0/f5/b0f5a259be992c863c641739441fea88e0f79742167f2db1f32b4ddbcac80c58.pdf"
            },
            {
                "text": "NTesco chooses Danfoss for high-efficiency SWRO at Vietnamese shrimp farm",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/54/04/5404232c980deac7c2fd3b722a560e19683f5da684dc3c6648483b8e354cfd57.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/54/04/5404232c980deac7c2fd3b722a560e19683f5da684dc3c6648483b8e354cfd57.pdf"
            },
            {
                "text": "iSave 21 Plus and iSave 40 Data sheet",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/86/3f/863fb4f0fad8ab8485128294e551a3b7570d5c465c29b1bf6c0ecc457dc4549f.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/86/3f/863fb4f0fad8ab8485128294e551a3b7570d5c465c29b1bf6c0ecc457dc4549f.pdf"
            },
            {
                "text": "APP and iSave overload protection",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/51/f2/51f2ad073f40fb37a33aba2a009ba8f6c5e4e7e815e509a6314cd90f3099f999.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/51/f2/51f2ad073f40fb37a33aba2a009ba8f6c5e4e7e815e509a6314cd90f3099f999.pdf"
            },
            {
                "text": "Membrane cleaning of the RO-system with iSave ERD",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/71/e7/71e77cc2f971f93c2f894af10204dbb6cdfe81d92f03d68c7706f148ae5a5de5.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/71/e7/71e77cc2f971f93c2f894af10204dbb6cdfe81d92f03d68c7706f148ae5a5de5.pdf"
            },
            {
                "text": "Parallel coupled APP pumps and iSave energy recovery device",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/78/a3/78a3d3ace8ceb0c97cbfd6c17fe560e1b7ce643b5cf08fa04bfe83a8f5a95105.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/78/a3/78a3d3ace8ceb0c97cbfd6c17fe560e1b7ce643b5cf08fa04bfe83a8f5a95105.pdf"
            },
            {
                "text": "Piping connections",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/2d/a5/2da5c7c0c12b113bec9e6697725f4d07a325775f0762b89d497869ce60eda2ee.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/2d/a5/2da5c7c0c12b113bec9e6697725f4d07a325775f0762b89d497869ce60eda2ee.pdf"
            },
            {
                "text": "Pressure Safety Valve in a seawater RO system",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d1/75/d175db242f1a94ecf2fa315df0f7b7b7ad309d4a4241ef52d956ffc69ad330f8.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d1/75/d175db242f1a94ecf2fa315df0f7b7b7ad309d4a4241ef52d956ffc69ad330f8.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715162672280"
        },
        "description": "Mounting orientation: Vertical; Horizontal, HP out flow [m³/h] [Max]: 41, HP out flow [gpm] [Max]: 181, Rated power [HP]: 0, Rated power [kW]: 0",
        "created_at": "2026-06-16 07:36:10",
        "variations": []
    }
}