    "data": {
        "id": 198268,
        "sku": "180F7040",
        "name": "Energy Recovery Device, ISAVE 70",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/180F7040",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 1043,
            "name": "iSave 50-70"
        },
        "categories": [
            {
                "id": 1043,
                "name": "iSave 50-70"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "698 Kilogram",
            "Net weight": "614.16 Kilogram",
            "Volume": "1624.104 Liter",
            "EAN": "5715162675823",
            "Type": "iSave 50-70",
            "Product group": "Energy Recovery Device",
            "Allowable working torque [lbf·ft] [Max]": "140 lbf∙ft",
            "Allowable working torque [Nm] [Max]": "190 N-m",
            "Ambient temperature [°C] [Max]": "50 °C",
            "Ambient temperature [°C] [Min]": "0 °C",
            "Ambient temperature [°F] [Max]": "122 °F",
            "Ambient temperature [°F] [Min]": "32 °F",
            "Approval": "CE",
            "Base frame": "Stainless",
            "CE evaluated": "Yes",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Country of origin": "Denmark",
            "Description": "iSave70 Vertical IEC200L 18.5kW 6p 50Hz",
            "Differential pressure HP in out [barg] [Max]": "5 barg",
            "Differential pressure HP in out [psig] [Max]": "72 psig",
            "Drain connection size [in]": "1/4 in",
            "Drain connection standard": "Metric",
            "Drain connection type": "BSPP",
            "EU RoHS compliance": "Yes",
            "EU RoHS exemption clause": "No",
            "Flow [gpm] [Min]": "220 gal/min",
            "Flow [m³/h] [Min]": "50 m³/h",
            "HP inlet connection size [in]": "3 in",
            "HP Inlet connection standard": "Victaulic",
            "HP inlet pressure [barg] [Min]": "40 barg",
            "HP inlet pressure [psig] [Min]": "580 psig",
            "HP inlet pressure, intermittent [barg] [Min]": "2 barg",
            "HP inlet pressure, intermittent [psig] [Min]": "29 psig",
            "HP out flow [gpm] [Max]": "308 gal/min",
            "HP out flow [m³/h] [Max]": "70 m³/h",
            "HP outlet connection size [in]": "3 in",
            "HP Outlet connection standard": "Victaulic",
            "HP outlet pressure [barg] [Max]": "83 barg",
            "HP outlet pressure [psig] [Max]": "1200 psig",
            "In scope of WEEE": "No",
            "IP protection class": "IP55",
            "LP in out @ max flow [psig]": "11 psig",
            "LP in out @ max. flow [barg]": "1 barg",
            "LP in out max. static test pressure [barg]": "13 barg",
            "LP in out max. static test pressure [psig]": "189 psig",
            "LP inlet allowable working flow [gpm] [Max]": "308 gal/min",
            "LP inlet allowable working flow [m³/h] [Max]": "70 m³/h",
            "LP Inlet allowable working pressure [barg] [Min]": "2 barg",
            "LP Inlet allowable working pressure [psig] [Min]": "29 psig",
            "LP inlet connection size [in]": "3 in",
            "LP Inlet connection standard": "Victaulic",
            "LP inlet pressure [barg] [Max]": "5 barg",
            "LP inlet pressure [psig] [Max]": "72 psig",
            "LP Inlet pressure peak [barg]": "10 barg",
            "LP Inlet pressure peak [psig]": "145 psig",
            "LP outlet connection size [in]": "3 in",
            "Lubrication flow at 60 [m³/h] [Max]": "1.5 m³/h",
            "Lubrication flow at 871 [gpm] [Max]": "6.6 gal/min",
            "Material type": "Duplex, Super Duplex",
            "Media temperature [°C] [Max]": "35 °C",
            "Media temperature [°C] [Min]": "2 °C",
            "Media temperature [°F] [Max]": "95 °F",
            "Media temperature [°F] [Min]": "36 °F",
            "Motor ambient temperature [°C] [Max]": "40 °C",
            "Motor ambient temperature [°F] [Max]": "104 °F",
            "Motor current [A]": "37 A",
            "Motor frame Size": "200L",
            "Motor insulation class": "B",
            "Motor poles": "6",
            "Motor standard": "IEC",
            "Motor Torque at nom. speed [lbf·ft]": "130.5 lbf∙ft",
            "Motor torque at nom. speed [Nm]": "177 N-m",
            "Motor voltage": "380-420V/660720V, 50 Hz, 440-480V, 60 Hz",
            "Mounting orientation": "Vertical",
            "Outside dimensions of packaging LxWxH [in]": "84,3x28,2x40,2",
            "Outside dimensions of packaging LxWxH [mm]": "2150x720x1025",
            "Product description": "iSave",
            "Rated power [HP]": "30 HP",
            "Rated power [kW]": "18.5 kW",
            "REACH Candidate List substances": "No",
            "Seal Material": "NBR",
            "Serviceable": "Yes",
            "Sound pressure level [dB(A)]": "86 dBA",
            "Speed [rpm] [Max]": "875 rpm",
            "Speed [rpm] [Min]": "650 rpm",
            "Starting torque [lbf·ft] [Max]": "132 lbf∙ft",
            "Starting torque [Nm] [Max]": "180 N-m",
            "Static test pressure HP in out [barg] [Max]": "108 barg",
            "Static test pressure HP in out [psig] [Max]": "1566 psig",
            "Type designation": "ISAVE 70",
            "UL evaluated": "No"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/c9/93/c993760aa13c71ac4a51f30e10ac193c1f3408eafd77f759ebd63c372fc2ced8.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/c9/93/c993760aa13c71ac4a51f30e10ac193c1f3408eafd77f759ebd63c372fc2ced8.jpg",
                "local_path": "danfoss/images/c9/93/c993760aa13c71ac4a51f30e10ac193c1f3408eafd77f759ebd63c372fc2ced8.jpg",
                "original_url": "https://assets.danfoss.com/photos/145196/ID236223356124-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Acciona relies on Danfoss pumps - builds SWRO plant and reduces energy consumption by 88 percentages",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d1/f9/d1f99f3d6c54fde2f3368ce15a04d4c93a8511344ae73f3f6c6c27aa9a7adef4.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d1/f9/d1f99f3d6c54fde2f3368ce15a04d4c93a8511344ae73f3f6c6c27aa9a7adef4.pdf"
            },
            {
                "text": "Enwa uses energy-efficient Danfoss technology in SWRO solution to keep salmon sustainably healty",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/02/84/02844b2f3adac15305cdb1320a90763bc6dea9b7f9d3908e7b8e1f6c20a05707.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/02/84/02844b2f3adac15305cdb1320a90763bc6dea9b7f9d3908e7b8e1f6c20a05707.pdf"
            },
            {
                "text": "Gefico and Danfoss install 1800 m3 day RO plant in record time",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3c/6a/3c6ac689abcb0ec470182bfa764e9fb7ac4d04bd3a9e7436fa67d7f197aee01d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3c/6a/3c6ac689abcb0ec470182bfa764e9fb7ac4d04bd3a9e7436fa67d7f197aee01d.pdf"
            },
            {
                "text": "Veolia Water Technologies and Danfoss retrofit municipal water plant to save 57 in energy",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/2b/59/2b5932198eb4d369500ec689baadd741e24801213ad81ee598963f56bf12ab4c.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/2b/59/2b5932198eb4d369500ec689baadd741e24801213ad81ee598963f56bf12ab4c.pdf"
            },
            {
                "text": "iSave 50 -70 Data sheet",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/85/8a/858a357f1303a839faf182a682e7074af5918a9db1c4002a2e719c45428acdff.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/85/8a/858a357f1303a839faf182a682e7074af5918a9db1c4002a2e719c45428acdff.pdf"
            },
            {
                "text": "APP and iSave overload protection",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/51/f2/51f2ad073f40fb37a33aba2a009ba8f6c5e4e7e815e509a6314cd90f3099f999.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/51/f2/51f2ad073f40fb37a33aba2a009ba8f6c5e4e7e815e509a6314cd90f3099f999.pdf"
            },
            {
                "text": "Piping connections",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/2d/a5/2da5c7c0c12b113bec9e6697725f4d07a325775f0762b89d497869ce60eda2ee.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/2d/a5/2da5c7c0c12b113bec9e6697725f4d07a325775f0762b89d497869ce60eda2ee.pdf"
            },
            {
                "text": "Pressure Safety Valve in a seawater RO system",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d1/75/d175db242f1a94ecf2fa315df0f7b7b7ad309d4a4241ef52d956ffc69ad330f8.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d1/75/d175db242f1a94ecf2fa315df0f7b7b7ad309d4a4241ef52d956ffc69ad330f8.pdf"
            },
            {
                "text": "Start and stop of the SWRO with iSave unit",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/66/e7/66e7a12cd629831b629a0d86593844fb34b9ba794333a9b451f40f2fef53a4d0.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/66/e7/66e7a12cd629831b629a0d86593844fb34b9ba794333a9b451f40f2fef53a4d0.pdf"
            },
            {
                "text": "Change of bearings in the iSave 50/70 Vane pump",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1a/4a/1a4a3f208df4b61d0e65e1948cb0242a21f032b613c1098f22e3e65a3e378397.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1a/4a/1a4a3f208df4b61d0e65e1948cb0242a21f032b613c1098f22e3e65a3e378397.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715162675823"
        },
        "description": "Mounting orientation: Vertical, HP out flow [m³/h] [Max]: 70, HP out flow [gpm] [Max]: 308, Rated power [HP]: 30, Rated power [kW]: 18.5",
        "created_at": "2026-06-16 07:36:10",
        "variations": []
    }
}