{
    "data": {
        "id": 201,
        "sku": "003Z1061",
        "name": "MSV-F2, DN 50, PN 16, Flange",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/003Z1061",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": null,
            "name": null
        },
        "categories": [],
        "series": null,
        "specifications": {
            "Quantity": "Units of measure",
            "Gross weight": "9.46 Kilogram",
            "Net weight": "8.7 Kilogram",
            "Volume": "15.797 Liter",
            "EAN": "5702421551387",
            "Type": "MSV-F2",
            "Product group": "Manual balancing",
            "China RoHS compliance": "Out of scope",
            "Connection types": "Flange",
            "Contains batteries": "No",
            "Description": "MSV-F2 DN 50 with test plugs, PN16, manual balancing valve",
            "Differential pressure over the valve [kPa] [Max]": "150 KPa",
            "Drain function": "No",
            "EU RoHS compliance": "Yes with exemptions",
            "EU RoHS exemption clause": "6(c)",
            "Kvs values [m³/h]": "53.8 m³/h",
            "Media temperature [°C] [Max]": "130 °C",
            "Media temperature [°C] [Min]": "-10 °C",
            "Pressure class": "PN 16",
            "REACH Candidate List substances": "Lead (CAS no. 7439-92-1)",
            "SCIP dossier no.": "b53622cd-50a2-4626-a23a-856f12c6983e",
            "SCIP dossier product name": "MSV-F2 MNF DN15-300",
            "Setting scale": "Yes",
            "Shut-off function": "Yes",
            "Test plugs": "With test plugs",
            "Valve body material": "Cast iron (EN-GJL-250)",
            "Valve size": "DN 50",
            "Proposition 65": "WARNING: Cancer and Reproductive Harmwww.p65warnings.ca.gov",
            "Visuals": "Document Category"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/98/e1/98e1027d72e2bda5032303d89e3809b0ac409b42ee2335e452795053c8378bfe.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/98/e1/98e1027d72e2bda5032303d89e3809b0ac409b42ee2335e452795053c8378bfe.jpg",
                "local_path": "danfoss/images/98/e1/98e1027d72e2bda5032303d89e3809b0ac409b42ee2335e452795053c8378bfe.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/136549/ID043036378511-0101_preview.jpg",
                "is_main": true
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/65/de/65de530efe4e781e1a16e2754bffe550ac7343601eedb94cb23d307df83de891.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/65/de/65de530efe4e781e1a16e2754bffe550ac7343601eedb94cb23d307df83de891.jpg",
                "local_path": "danfoss/images/65/de/65de530efe4e781e1a16e2754bffe550ac7343601eedb94cb23d307df83de891.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/14266/ID159286513881-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/de/76/de7615bee8fc17e02bc5fd380805c6df3809d87630d9b54e5aa1e96f4ec9db8b.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/de/76/de7615bee8fc17e02bc5fd380805c6df3809d87630d9b54e5aa1e96f4ec9db8b.jpg",
                "local_path": "danfoss/images/de/76/de7615bee8fc17e02bc5fd380805c6df3809d87630d9b54e5aa1e96f4ec9db8b.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/19635/ID159286513844-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/c7/b5/c7b57f19903112fa0f8aefe30dccdfcfbf6a2b63ee66d5b5efee1cbd2e5beac9.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/c7/b5/c7b57f19903112fa0f8aefe30dccdfcfbf6a2b63ee66d5b5efee1cbd2e5beac9.jpg",
                "local_path": "danfoss/images/c7/b5/c7b57f19903112fa0f8aefe30dccdfcfbf6a2b63ee66d5b5efee1cbd2e5beac9.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/136542/ID043036385513-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/55/ed/55ed9e9f9f6b734cffb7da906f3a9b5ca190b6d7cd0c45368545a211799f8a98.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/55/ed/55ed9e9f9f6b734cffb7da906f3a9b5ca190b6d7cd0c45368545a211799f8a98.jpg",
                "local_path": "danfoss/images/55/ed/55ed9e9f9f6b734cffb7da906f3a9b5ca190b6d7cd0c45368545a211799f8a98.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/136544/ID043036393515-0101_preview.jpg",
                "is_main": false
            }
        ],
        "pdf_documents": [
            {
                "text": "Design Support Center | Design services for hydronic HVAC systems",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/03/c3/03c30486959059993ea712e3ca80e2b8c8ff511b52edee838256f2dd661f865b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/03/c3/03c30486959059993ea712e3ca80e2b8c8ff511b52edee838256f2dd661f865b.pdf"
            },
            {
                "text": "EU declaration BF27112024-en01",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/39/2a/392a53a6377ed7dd9b3f27b1f92c9b345775fac6a97a2338a2c117623bb9c8ee.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/39/2a/392a53a6377ed7dd9b3f27b1f92c9b345775fac6a97a2338a2c117623bb9c8ee.pdf"
            },
            {
                "text": "Butterfly, other valves, Manual balancing valves, one pipe solution valves and hot water balancing valves",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/b6/aa/b6aa8281e232efadb699972d33e62492f04206d9f2fea7dbc5cec007f5f71fbc.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/b6/aa/b6aa8281e232efadb699972d33e62492f04206d9f2fea7dbc5cec007f5f71fbc.pdf"
            },
            {
                "text": "CE-0062-PED-H-DAF 002-24-DNK-rev-A",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/be/5e/be5eb0ad38f6fb310e60903c68ba2f03a99acc4f359c0660beabd60dac3130d5.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/be/5e/be5eb0ad38f6fb310e60903c68ba2f03a99acc4f359c0660beabd60dac3130d5.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5702421551387"
        },
        "description": "MSV-F2 DN 50 with test plugs, PN16, manual balancing valve",
        "created_at": "2026-06-14 00:05:23",
        "variations": []
    }
}