    "data": {
        "id": 244,
        "sku": "003Z8200",
        "name": "AB-QM, DN 15 LF, Test plugs: With test plugs",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/003Z8200",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": null,
            "name": null
        },
        "categories": [],
        "series": null,
        "specifications": {
            "Quantity": "Units of measure",
            "Gross weight": "0.592 Kilogram",
            "Net weight": "0.535 Kilogram",
            "Volume": "1.013 Liter",
            "EAN": "5714279039207",
            "Type": "AB-QM",
            "Product group": "Pressure independent balancing and control valves",
            "Actuator connection": "M30 x 1.5",
            "China RoHS compliance": "Out of scope",
            "Connection types": "External thread ISO 228/1G ¾A",
            "Contains batteries": "No",
            "Description": "AB-QM DN 15 Low flow, with test plugs, External thread, PN25, pressure independent balancing and control valve",
            "Differential pressure [kPa] [Max]": "600 KPa",
            "Differential pressure [kPa] [Min]": "16 KPa",
            "EPD available": "Yes",
            "EU RoHS compliance": "Yes with exemptions",
            "EU RoHS exemption clause": "6(c)",
            "Flow limitation": "Yes",
            "Flow nominal [m³/h]": "0.2 m³/h",
            "Leakage rate with recommended actuator (IEC 60534-4)": "Class IV",
            "Media temperature [°C] [Max]": "95 °C",
            "Media temperature [°C] [Min]": "-20 °C",
            "Mounting position": "Supply / return pipe",
            "Pressure class": "PN 25",
            "REACH Candidate List substances": "Lead (CAS no. 7439-92-1)",
            "SCIP dossier no.": "b2a642ef-a80a-42a1-a9af-6eb95466dd1d",
            "SCIP dossier product name": "AB-QM 10-32 - 4g",
            "Setting range [%] [max]": "100 %",
            "Setting range [%] [min]": "10 %",
            "Setting scale": "Yes",
            "Shut-off function": "Yes",
            "Shut-off leakage rate (ISO 5208)": "Rate A",
            "Storage and Transport temperature [°C] [Max]": "70 °C",
            "Storage and Transport temperature [°C] [Min]": "-40 °C",
            "Stroke [mm]": "4 mm",
            "Test plugs": "With test plugs",
            "Valve body material": "DZR Brass (CW 602N)",
            "Valve size": "Low flowDN 15 LF",
            "Version": "AB-QM 4.0",
            "Proposition 65": "WARNING: Cancer and Reproductive Harmwww.p65warnings.ca.gov",
            "Visuals": "Document Category"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/fe/b7/feb7903bf501161f423eefa6ff42192dee04bab22ce4dee75a114a386c2ff81b.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/fe/b7/feb7903bf501161f423eefa6ff42192dee04bab22ce4dee75a114a386c2ff81b.jpg",
                "local_path": "danfoss/images/fe/b7/feb7903bf501161f423eefa6ff42192dee04bab22ce4dee75a114a386c2ff81b.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/133533/ID318152863698-0101_preview.jpg",
                "is_main": true
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/22/23/22232b8607700bd8414e6f0b2fefae68ab36f7599fa84650d46ad19c0a3085c4.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/22/23/22232b8607700bd8414e6f0b2fefae68ab36f7599fa84650d46ad19c0a3085c4.jpg",
                "local_path": "danfoss/images/22/23/22232b8607700bd8414e6f0b2fefae68ab36f7599fa84650d46ad19c0a3085c4.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/133538/ID318154241700-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/98/6d/986dfd7d501e0cfc21a2b862e61f40371ff34e3f433b9d9bdc58764b12e46b2b.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/98/6d/986dfd7d501e0cfc21a2b862e61f40371ff34e3f433b9d9bdc58764b12e46b2b.jpg",
                "local_path": "danfoss/images/98/6d/986dfd7d501e0cfc21a2b862e61f40371ff34e3f433b9d9bdc58764b12e46b2b.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/868/ID332186518821-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/8b/9b/8b9b0a6637ebc4b1928633e2e34733030aba1e344c35a45866d45e2677c5f0ea.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/8b/9b/8b9b0a6637ebc4b1928633e2e34733030aba1e344c35a45866d45e2677c5f0ea.jpg",
                "local_path": "danfoss/images/8b/9b/8b9b0a6637ebc4b1928633e2e34733030aba1e344c35a45866d45e2677c5f0ea.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/201530/ID414864039413-0201_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/aa/11/aa112f1c8e99bce3c98156d20627b3efa41bdf5df2f3ca4b923795aae068a543.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/aa/11/aa112f1c8e99bce3c98156d20627b3efa41bdf5df2f3ca4b923795aae068a543.jpg",
                "local_path": "danfoss/images/aa/11/aa112f1c8e99bce3c98156d20627b3efa41bdf5df2f3ca4b923795aae068a543.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/201495/ID414864035412-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/6b/ab/6bab6ddce41ef0e71154b881506218fcb61ee4fa1b2a9340b97cc2089b8ca9a4.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/6b/ab/6bab6ddce41ef0e71154b881506218fcb61ee4fa1b2a9340b97cc2089b8ca9a4.jpg",
                "local_path": "danfoss/images/6b/ab/6bab6ddce41ef0e71154b881506218fcb61ee4fa1b2a9340b97cc2089b8ca9a4.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/201496/ID414864048416-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/ed/d7/edd768785a7315790fdb2b18f2ba55ab7cfa9460747037deed8a3dffa7f99124.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/ed/d7/edd768785a7315790fdb2b18f2ba55ab7cfa9460747037deed8a3dffa7f99124.jpg",
                "local_path": "danfoss/images/ed/d7/edd768785a7315790fdb2b18f2ba55ab7cfa9460747037deed8a3dffa7f99124.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/201497/ID414864045415-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/76/78/76787f6b3db2ef24bf9f48de05bde89514ddf4ab2c0fbedc7a0694367c579720.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/76/78/76787f6b3db2ef24bf9f48de05bde89514ddf4ab2c0fbedc7a0694367c579720.jpg",
                "local_path": "danfoss/images/76/78/76787f6b3db2ef24bf9f48de05bde89514ddf4ab2c0fbedc7a0694367c579720.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/201529/ID414864042414-0201_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/34/37/3437cebd418e70cbfd29f1e65a742dffa729a9d32a36d12316182cc20838a6d1.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/34/37/3437cebd418e70cbfd29f1e65a742dffa729a9d32a36d12316182cc20838a6d1.jpg",
                "local_path": "danfoss/images/34/37/3437cebd418e70cbfd29f1e65a742dffa729a9d32a36d12316182cc20838a6d1.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/205263/ID318153947699-0102_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/fa/46/fa46b609604e919ed79cb6273d3b5a6d0973a3d034cfdd689b589ad2895ebf0e.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/fa/46/fa46b609604e919ed79cb6273d3b5a6d0973a3d034cfdd689b589ad2895ebf0e.jpg",
                "local_path": "danfoss/images/fa/46/fa46b609604e919ed79cb6273d3b5a6d0973a3d034cfdd689b589ad2895ebf0e.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/230344/ID398940400149-0201_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/f5/21/f52190f3b7ed43f76a7f14b69154a961e4fec30741f4346641e0cf42fad09f04.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/f5/21/f52190f3b7ed43f76a7f14b69154a961e4fec30741f4346641e0cf42fad09f04.jpg",
                "local_path": "danfoss/images/f5/21/f52190f3b7ed43f76a7f14b69154a961e4fec30741f4346641e0cf42fad09f04.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/230341/ID398940397148-0201_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/36/16/3616eb0bff2260c1ad5845b41e3b2e74b5686636f5b5801274c7dec87147fea1.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/36/16/3616eb0bff2260c1ad5845b41e3b2e74b5686636f5b5801274c7dec87147fea1.jpg",
                "local_path": "danfoss/images/36/16/3616eb0bff2260c1ad5845b41e3b2e74b5686636f5b5801274c7dec87147fea1.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/230343/ID398940403150-0201_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/52/47/524788e77d6e77fb4d15e27af03daa531c8dfbfecc434f5611e0232bee4269e8.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/52/47/524788e77d6e77fb4d15e27af03daa531c8dfbfecc434f5611e0232bee4269e8.jpg",
                "local_path": "danfoss/images/52/47/524788e77d6e77fb4d15e27af03daa531c8dfbfecc434f5611e0232bee4269e8.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/230342/ID398940394147-0201_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/65/de/65de530efe4e781e1a16e2754bffe550ac7343601eedb94cb23d307df83de891.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/65/de/65de530efe4e781e1a16e2754bffe550ac7343601eedb94cb23d307df83de891.jpg",
                "local_path": "danfoss/images/65/de/65de530efe4e781e1a16e2754bffe550ac7343601eedb94cb23d307df83de891.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/6605/ID332186518828-0101_preview.jpg",
                "is_main": false
            }
        ],
        "pdf_documents": [
            {
                "text": "AB-QM Brochure - General",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/21/4b/214bb314fef4b7bf2026bcb6d5f52293fc32a915ecf94a4b7703f76338bd6eaa.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/21/4b/214bb314fef4b7bf2026bcb6d5f52293fc32a915ecf94a4b7703f76338bd6eaa.pdf"
            },
            {
                "text": "AB-QM Brochure - Hospitals",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/76/a4/76a4023ab5fa57c18e69709641b6ea606801eb548530ca71160863294108d8de.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/76/a4/76a4023ab5fa57c18e69709641b6ea606801eb548530ca71160863294108d8de.pdf"
            },
            {
                "text": "AB-QM Brochure - Universities",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/29/dd/29dda35af6a099849c8e27123966d421b8004dc198ab51dac2dece72d128a5e3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/29/dd/29dda35af6a099849c8e27123966d421b8004dc198ab51dac2dece72d128a5e3.pdf"
            },
            {
                "text": "AB-QM Valves Raise Profits for CUBO Organic Poultry Farmer VZA7N122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/09/db/09db8a47ec2d60d396b8d72354ae2bd6578fc5b57d03b3957f75f54990e9af26.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/09/db/09db8a47ec2d60d396b8d72354ae2bd6578fc5b57d03b3957f75f54990e9af26.pdf"
            },
            {
                "text": "Engineering Tomorrow Solves Complex Energy and Comfort Problems for Elementary School",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3a/4f/3a4fb8414b674b56835c9264752dd973dda86a45142bc59db8385e18c7bbfd1a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3a/4f/3a4fb8414b674b56835c9264752dd973dda86a45142bc59db8385e18c7bbfd1a.pdf"
            },
            {
                "text": "Hydronic Analyzer Tests Prove Significant Savings in Malaysian Hotel VZA7S122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f9/98/f998696fe3342386c08ceb4a730f5b2d2966e11fb35014f251d7aa325bc99393.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f9/98/f998696fe3342386c08ceb4a730f5b2d2966e11fb35014f251d7aa325bc99393.pdf"
            },
            {
                "text": "Keeping it Cool in Downtown Dubai, Burj Khalifa, VZA7T122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/43/6a/436a99f18ece75e2103bdeb263617907c0504077f9c545422c8eb337e31eb64a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/43/6a/436a99f18ece75e2103bdeb263617907c0504077f9c545422c8eb337e31eb64a.pdf"
            },
            {
                "text": "Monumental Energy Savings in Cooling System, Consplant Tower VZA7Q122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/0e/1e/0e1e5ed8ec2999b78531d08fe8e731b754faa0acd1bc3461c432996e69f9d1c1.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/0e/1e/0e1e5ed8ec2999b78531d08fe8e731b754faa0acd1bc3461c432996e69f9d1c1.pdf"
            },
            {
                "text": "NA AB-QM Project References",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d3/e2/d3e2a233dec190dcffbb12cb61926db80606b7c0127345ab101916299699eaff.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d3/e2/d3e2a233dec190dcffbb12cb61926db80606b7c0127345ab101916299699eaff.pdf"
            },
            {
                "text": "Rochester Institute of Technology (RIT) Case Study",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a0/65/a0655e22948b2df93e1c7f2fdc2fed4fdf24635f6f2993a2cdcc427bf3dfed20.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a0/65/a0655e22948b2df93e1c7f2fdc2fed4fdf24635f6f2993a2cdcc427bf3dfed20.pdf"
            },
            {
                "text": "Second Life for One-Pipe Heating System in Moscow, Russia VZA7U122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/74/0b/740ba01d771fb19149d46813ff0a8bca6c4795ca00494c426daadcbdc99c12c1.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/74/0b/740ba01d771fb19149d46813ff0a8bca6c4795ca00494c426daadcbdc99c12c1.pdf"
            },
            {
                "text": "Sky-High Comfort, the Sustainable Way, Sky Tower VZA7R122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/c0/4e/c04e22ccb0490f56bd86dc651c552a899993ea4218e255a54530b9ad8bfc3cc7.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/c0/4e/c04e22ccb0490f56bd86dc651c552a899993ea4218e255a54530b9ad8bfc3cc7.pdf"
            },
            {
                "text": "The Park - Small Valves Introduce Big Changes to Building Efficiency and Occupant Comfort VZA70122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ae/00/ae00824a120eee8e65050e2188211acbffe2093b91d8818caf6645a365c14181.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ae/00/ae00824a120eee8e65050e2188211acbffe2093b91d8818caf6645a365c14181.pdf"
            },
            {
                "text": "UMKC Student Union Building Chooses Danfoss AB-QM",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/24/34/2434826593ec5131273d8a40b70b457b0d8df7e7bccd3cabce71bb240a11ccc0.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/24/34/2434826593ec5131273d8a40b70b457b0d8df7e7bccd3cabce71bb240a11ccc0.pdf"
            },
            {
                "text": "AB-QM™ Interactive Quick Select Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/63/ee/63eef3e997f4ac1992f7f3f80e86fe153b8e19d0c944212cc93967c1eeb207ab.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/63/ee/63eef3e997f4ac1992f7f3f80e86fe153b8e19d0c944212cc93967c1eeb207ab.pdf"
            },
            {
                "text": "Design Support Center | Design services for hydronic HVAC systems",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/03/c3/03c30486959059993ea712e3ca80e2b8c8ff511b52edee838256f2dd661f865b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/03/c3/03c30486959059993ea712e3ca80e2b8c8ff511b52edee838256f2dd661f865b.pdf"
            },
            {
                "text": "AB-QM NovoCon flow checker DN 40-100",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/fe/b3/feb3b7f51c2e83a44c638a28950572b0ee9dcc848880a1aa1a58ef0805e1bc65.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/fe/b3/feb3b7f51c2e83a44c638a28950572b0ee9dcc848880a1aa1a58ef0805e1bc65.pdf"
            },
            {
                "text": "AB-QM Valve High Flow ISO Flange Submittal VLA7H122",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/97/65/9765facb10773f47e7a64136659fc2da4e78929f1c66d247cbca977f18edd7a1.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/97/65/9765facb10773f47e7a64136659fc2da4e78929f1c66d247cbca977f18edd7a1.pdf"
            },
            {
                "text": "AB-QM Valve Neck Version Distinction",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/77/90/779018d53caea3f4d5b94ed8e79eeb0c619f77d6cf5d07aeda63fe3afc182771.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/77/90/779018d53caea3f4d5b94ed8e79eeb0c619f77d6cf5d07aeda63fe3afc182771.pdf"
            },
            {
                "text": "AB-QM Valve Submittal - 1.5\" to 2\"",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/9b/82/9b82c12f7134f638be10392b5f248ffd1d254ca8ecf628c1d6426df80c76f898.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/9b/82/9b82c12f7134f638be10392b5f248ffd1d254ca8ecf628c1d6426df80c76f898.pdf"
            },
            {
                "text": "AB-QM Valve Submittal - 2.5\" to 4\"",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/a6/34/a6342d619859ec9c7cbe1caac1241c65f6a7ac0eb5ea603ac344cffef9132867.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/a6/34/a6342d619859ec9c7cbe1caac1241c65f6a7ac0eb5ea603ac344cffef9132867.pdf"
            },
            {
                "text": "AB-QM Valve Submittal - 2.5\" to 4\" High Flow",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/cd/88/cd88a5088806ab4531bf4584fa74d4f12ae15cae50c4094d97777a0370696a7e.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/cd/88/cd88a5088806ab4531bf4584fa74d4f12ae15cae50c4094d97777a0370696a7e.pdf"
            },
            {
                "text": "AB-QM Valve Submittal - 5\" to 10\", High Flow",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/e1/38/e138ff7daa47b3205e8e1de32b470d81e82ff246f6d64c80a4e5c10fc109403b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/e1/38/e138ff7daa47b3205e8e1de32b470d81e82ff246f6d64c80a4e5c10fc109403b.pdf"
            },
            {
                "text": "AB-QM Valve Submittal - 5\" to 6\", 2PT",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/31/2c/312ccb2644d397341fa322b35489bee7a554047a3bfd8ae1a40de395b2c3891c.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/31/2c/312ccb2644d397341fa322b35489bee7a554047a3bfd8ae1a40de395b2c3891c.pdf"
            },
            {
                "text": "AB-QM Valve Submittal - 8\" to 10\", ISO",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/63/ca/63ca8bfbc5730007ce43fb6fe332010d749a008135e4f9253e6c844908bb5b70.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/63/ca/63ca8bfbc5730007ce43fb6fe332010d749a008135e4f9253e6c844908bb5b70.pdf"
            },
            {
                "text": "EU declaration BF27112024-en01",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/39/2a/392a53a6377ed7dd9b3f27b1f92c9b345775fac6a97a2338a2c117623bb9c8ee.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/39/2a/392a53a6377ed7dd9b3f27b1f92c9b345775fac6a97a2338a2c117623bb9c8ee.pdf"
            },
            {
                "text": "Automatic balancing and Pressure independent control valves",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/d5/db/d5db06e81642de8caba541c8297552b46c36f0b2a9e722e91951c2a980fe857e.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/d5/db/d5db06e81642de8caba541c8297552b46c36f0b2a9e722e91951c2a980fe857e.pdf"
            },
            {
                "text": "Danfoss MD BF10012025-en01-01",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/65/d9/65d95e9841aa5061307ac14619ac9c0a356bc405ef7047924718f8f57c211290.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/65/d9/65d95e9841aa5061307ac14619ac9c0a356bc405ef7047924718f8f57c211290.pdf"
            },
            {
                "text": "Danfoss MD BF206986516296en-000501.01",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/04/3f/043fd773b4145a3d4d7141bec5af3b4f5ed13cb07cf554af0b5307c4f8691d31.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/04/3f/043fd773b4145a3d4d7141bec5af3b4f5ed13cb07cf554af0b5307c4f8691d31.pdf"
            },
            {
                "text": "Declaration of Energy Classes (BACS) - EN ISO 52120-1 and EN ISO 16484-4",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/12/04/1204ad5b12b6c49b11054dbac6597dae8e9ac89c927d6d84f95e609ef85b6cb2.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/12/04/1204ad5b12b6c49b11054dbac6597dae8e9ac89c927d6d84f95e609ef85b6cb2.pdf"
            },
            {
                "text": "CE-0062-PED-H-DAF 002-24-DNK-rev-A",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/be/5e/be5eb0ad38f6fb310e60903c68ba2f03a99acc4f359c0660beabd60dac3130d5.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/be/5e/be5eb0ad38f6fb310e60903c68ba2f03a99acc4f359c0660beabd60dac3130d5.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5714279039207"
        },
        "description": "AB-QM DN 15 Low flow, with test plugs, External thread, PN25, pressure independent balancing and control valve",
        "created_at": "2026-06-14 00:05:23",
        "variations": []
    }
}