    "data": {
        "id": 5157,
        "sku": "061B7035",
        "name": "Test Valve, MBV 5000",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/061B7035",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": null,
            "name": null
        },
        "categories": [],
        "series": null,
        "specifications": {
            "Quantity": "Units of measure",
            "Gross weight": "0.786 Kilogram",
            "Net weight": "0.721 Kilogram",
            "Volume": "1.118 Liter",
            "EAN": "5702423208135",
            "Type": "MBV 5000",
            "Product group": "Shut-off and regulating valves",
            "Product Name Description": "Test Valve",
            "Ambient temperature range [°C] [max]": "120 °C",
            "Ambient temperature range [°C] [min]": "-20 °C",
            "Ambient temperature range [°F] [Max]": "248 °F",
            "Ambient temperature range [°F] [Min]": "-4 °F",
            "Approval": "EACLLC CDC EURO-TYSKRoHS",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "EU RoHS compliance": "Out of scope",
            "MiniMess included": "Yes",
            "Number of inputs [pc]": "1 pc",
            "Number of outputs [pc]": "2 pc",
            "Output connection type": "Flange",
            "Packing format": "Multi pack",
            "Pressure connection size": "12 x 1.5",
            "Pressure connection standard": "ISO 6149-1",
            "Pressure connection type": "M",
            "Pressure Male/Female": "Female",
            "Pressure range (Pi) [bar] [Max]": "120 bar",
            "Pressure range (Pi) [bar] [Min]": "0 bar",
            "Pressure range (Pi) [bar] oil [Max]": "180 bar",
            "Pressure range (Pi) [bar] oil [Min]": "0 bar",
            "Pulse-snubber": "No",
            "Quantity per packing format": "18 pc",
            "REACH Candidate List substances": "Lead (CAS no. 7439-92-1)",
            "SCIP dossier no.": "cd7d33e0-ff13-4f81-9c95-994a26062075",
            "SCIP dossier product name": "MBV 1000-5000",
            "Specification key": "MBV5000-321X",
            "Test function": "Common",
            "Test pressure connection size": "16 x 2",
            "Test pressure connection type": "M",
            "Proposition 65": "WARNING: Cancer and Reproductive Harmwww.p65warnings.ca.gov",
            "Visuals": "Document Category"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/35/ae/35aee1a640ada28abfc0434596b0f08cfb4254f68c1fbeed06266ecfcbc9e9fd.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/35/ae/35aee1a640ada28abfc0434596b0f08cfb4254f68c1fbeed06266ecfcbc9e9fd.jpg",
                "local_path": "danfoss/images/35/ae/35aee1a640ada28abfc0434596b0f08cfb4254f68c1fbeed06266ecfcbc9e9fd.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/17621/ID318042158560-0101_preview.jpg",
                "is_main": true
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/e7/69/e7690d7660c4fc5225623171ce9e7c65c8e6c8ac7a8d8779c751a7777befd543.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/e7/69/e7690d7660c4fc5225623171ce9e7c65c8e6c8ac7a8d8779c751a7777befd543.jpg",
                "local_path": "danfoss/images/e7/69/e7690d7660c4fc5225623171ce9e7c65c8e6c8ac7a8d8779c751a7777befd543.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/384179/ID487101891318-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/f0/fa/f0fa011ab8a3256a0d0d54573237aefd429d220a5a053defadedc4ea3dbf9dc8.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/f0/fa/f0fa011ab8a3256a0d0d54573237aefd429d220a5a053defadedc4ea3dbf9dc8.jpg",
                "local_path": "danfoss/images/f0/fa/f0fa011ab8a3256a0d0d54573237aefd429d220a5a053defadedc4ea3dbf9dc8.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/384177/ID487101841316-0101_preview.jpg",
                "is_main": false
            }
        ],
        "pdf_documents": [
            {
                "text": "Danfoss solutions for Air Handling Units and Rooftops",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/e4/a0/e4a021c9b2058f1bdb87c92f976259499ce239e3de637bba8fc23e54b0f6130d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/e4/a0/e4a021c9b2058f1bdb87c92f976259499ce239e3de637bba8fc23e54b0f6130d.pdf"
            },
            {
                "text": "Test valve type MBV 5000",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/b7/e4/b7e46a731d0c0eb214af59468f2e9b271c5cf92328040764b05398aae2905eb2.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/b7/e4/b7e46a731d0c0eb214af59468f2e9b271c5cf92328040764b05398aae2905eb2.pdf"
            },
            {
                "text": "Test valve, type MBV 5000",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/5f/97/5f97e7a9be501cd9cb3b89dec72747ce0ca766bde6f82620ec04ca9b9a492beb.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/5f/97/5f97e7a9be501cd9cb3b89dec72747ce0ca766bde6f82620ec04ca9b9a492beb.pdf"
            },
            {
                "text": "Shut-off and regulating valves MBV",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3b/5e/3b5ee6bee276e531d3f152960f1769ca912024de436155ea6568715c5e7f05b3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3b/5e/3b5ee6bee276e531d3f152960f1769ca912024de436155ea6568715c5e7f05b3.pdf"
            },
            {
                "text": "ID487101911319-0101.pdf",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/fb/ac/fbacf3121f9a33ac065c122fd891a4f1a6f2d74d3b5db587289534e9ebbb333b.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/fb/ac/fbacf3121f9a33ac065c122fd891a4f1a6f2d74d3b5db587289534e9ebbb333b.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5702423208135"
        },
        "description": "Pressure connection type: M, Pressure connection size: 12 x 1.5, Pressure range (Pi) [bar]: 0 - 120",
        "created_at": "2026-06-14 00:05:24",
        "variations": []
    }
}