    "data": {
        "id": 6062,
        "sku": "068-2008",
        "name": "Orifice for expansion valve, ORF, R407A; R134a/R513A; R23; R455A; R407C; R236fa; R452A; R454C; R404A/R507A; R1234yf; R448A; R22/R407C; R449A",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/068-2008",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": null,
            "name": null
        },
        "categories": [],
        "series": null,
        "specifications": {
            "Quantity": "Units of measure",
            "Gross weight": "0.018 Kilogram",
            "Net weight": "0.013 Kilogram",
            "Volume": "0.017 Liter",
            "EAN": "5702422020400",
            "Type": "ORF",
            "Product group": "Expansion valves",
            "Product Name Description": "Orifice for expansion valve",
            "Approval": "EACLLC CDC TYSK",
            "Category": "Art. 4, par. 3",
            "China RoHS compliance": "Out of scope",
            "Contains batteries": "No",
            "Design": "SAE flare only",
            "EU RoHS compliance": "Yes with exemptions",
            "EU RoHS exemption clause": "6(a)6(c)",
            "Fluid Group": "1",
            "Orifice size": "05",
            "Packing format": "Multi pack",
            "Parts Program name": "T2/TE2",
            "Product accessories": "TXV accessories",
            "Quantity per packing format": "25 pc",
            "Rated cap. cond. Range N [IMP]": "tcond=100 ºFtevap=40 ºFtliq=98 ºF",
            "Rated cap. cond. Range N [SI]": "tcond=38 ºCtevap=4.4 ºCtliq=37 ºC",
            "Rated cap. R1234yf, N [kW]": "5.89 kW",
            "Rated cap. R1234yf, N [TR]": "1.67 TR",
            "Rated cap. R134a, Range N [kW]": "8.4 kW",
            "Rated cap. R134a, Range N [TR]": "2.4 TR",
            "Rated cap. R22, Range B [kW]": "7.3 kW",
            "Rated cap. R22, Range B [TR]": "2.1 TR",
            "Rated cap. R22, Range N [kW]": "16.7 kW",
            "Rated cap. R22, Range N [TR]": "4.8 TR",
            "Rated cap. R404A, Range B [kW]": "5.9 kW",
            "Rated cap. R404A, Range B [TR]": "1.7 TR",
            "Rated cap. R404A, Range N [kW]": "13 kW",
            "Rated cap. R404A, Range N [TR]": "3.7 TR",
            "Rated cap. R407C, Range N [kW]": "16.5 kW",
            "Rated cap. R407C, Range N [TR]": "4.7 TR",
            "Rated cap. R452A, Range N [kW]": "12.62 kW",
            "Rated cap. R452A, Range N [TR]": "3.59 TR",
            "Rated cap. R454C, Range N [kW]": "11.84 kW",
            "Rated cap. R454C, Range N [TR]": "3.37 TR",
            "Rated cap. R455A, Range N [kW]": "14.67 kW",
            "Rated cap. R455A, Range N [TR]": "4.17 TR",
            "Rated cap. R507, Range B [kW]": "5.9 kW",
            "Rated cap. R507, Range B [TR]": "1.7 TR",
            "Rated cap. R507, Range N [kW]": "13 kW",
            "Rated cap. R507, Range N [TR]": "3.7 TR",
            "Rated cap. R513A, Range N [kW]": "6.9 kW",
            "Rated cap. R513A, Range N [TR]": "2 TR",
            "REACH Candidate List substances": "Lead (CAS no. 7439-92-1)",
            "Refrigerants": "R134a/R513AR22/R407CR23R236faR404A/R507AR407AR407CR448AR449AR452AR1234yfR454CR455ARead more",
            "SCIP dossier no.": "c164ed45-f10d-4d73-9eae-355ccb479f4b",
            "SCIP dossier product name": "T2 /TE2 - Thermostatic Expansion Valve",
            "Serviceable": "No",
            "Temperature range [°C] [Max]": "10 °C",
            "Temperature range [°C] [Min]": "-40 °C",
            "Temperature range [°F] [Max]": "50 °F",
            "Temperature range [°F] [Min]": "-40 °F",
            "UA address": "UA_2L.png",
            "Used for product": "T 2TE 2",
            "Proposition 65": "WARNING: Cancer and Reproductive Harmwww.p65warnings.ca.gov",
            "Visuals": "Document Category",
            "Product type": "SPARE PART, Used for product: T 2; TE 2, Type designation: Filter, Filter",
            "Temperature range [°F]": "-40 - 50, Pressure equalization: Externally equalized"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/a7/5b/a75bdceb6c0542116143fb66bdfe2ae0a0d24e60533e8a930df187943e97215f.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/a7/5b/a75bdceb6c0542116143fb66bdfe2ae0a0d24e60533e8a930df187943e97215f.jpg",
                "local_path": "danfoss/images/a7/5b/a75bdceb6c0542116143fb66bdfe2ae0a0d24e60533e8a930df187943e97215f.jpg",
                "original_url": "https://assets.danfoss.com/photos/preview/114591/ID107324437861-0101_preview.jpg",
                "is_main": true
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/0a/3b/0a3be21de60b5dddb251f2de99f846bfd0a0b7ab93822dafee7c62ee6aa5fcc2.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/0a/3b/0a3be21de60b5dddb251f2de99f846bfd0a0b7ab93822dafee7c62ee6aa5fcc2.jpg",
                "local_path": "danfoss/images/0a/3b/0a3be21de60b5dddb251f2de99f846bfd0a0b7ab93822dafee7c62ee6aa5fcc2.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/394530/ID487509076707-0101_preview.jpg",
                "is_main": false
            },
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/52/f7/52f713d9aee73d4d17cfff14ab91623e170b3e4373780e1e5976f9ebaa284cd2.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/52/f7/52f713d9aee73d4d17cfff14ab91623e170b3e4373780e1e5976f9ebaa284cd2.jpg",
                "local_path": "danfoss/images/52/f7/52f713d9aee73d4d17cfff14ab91623e170b3e4373780e1e5976f9ebaa284cd2.jpg",
                "original_url": "https://assets.danfoss.com/drawings/preview/394528/ID487509025705-0101_preview.jpg",
                "is_main": false
            }
        ],
        "pdf_documents": [
            {
                "text": "Overview Brochure Thermostatic Expansion Valves",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/50/ab/50ab2853e655a2be3d5c720e2d32b5efa4b32cb49666d462406acdd788559fd7.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/50/ab/50ab2853e655a2be3d5c720e2d32b5efa4b32cb49666d462406acdd788559fd7.pdf"
            },
            {
                "text": "2026 Quick Select Guide - Refrigeration and Air Conditioning Components",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/35/19/3519e833ff6160e509525491b370cae4f299c080c8ed0ca64131d9324633f6f6.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/35/19/3519e833ff6160e509525491b370cae4f299c080c8ed0ca64131d9324633f6f6.pdf"
            },
            {
                "text": "Injection valve Type TXI 2",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/b5/9c/b59c060a59f39e09a86bcc2f37ca42b7a651a837e3466992625df6a6f063d9fa.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/b5/9c/b59c060a59f39e09a86bcc2f37ca42b7a651a837e3466992625df6a6f063d9fa.pdf"
            },
            {
                "text": "Thermostatic expansion valve Type T 2 / TE 2",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/30/2f/302fc7b1afd28dbfd0c06af4393d463b85850a5139bee6b7c37ec699d817eb38.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/30/2f/302fc7b1afd28dbfd0c06af4393d463b85850a5139bee6b7c37ec699d817eb38.pdf"
            },
            {
                "text": "Service on ice machines with R404A, type TU service kit",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ed/b4/edb40f49cbd678a9265b7639cca9c05ab81ca6f53ba6979f1654e4b9d0d2b5be.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ed/b4/edb40f49cbd678a9265b7639cca9c05ab81ca6f53ba6979f1654e4b9d0d2b5be.pdf"
            },
            {
                "text": "T2, TE 2 valves, adaptor, orifice",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/88/e3/88e3f67f5bb705fd1d959b4d84881438c379fc7a9c4580c0dd239bcf93587baa.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/88/e3/88e3f67f5bb705fd1d959b4d84881438c379fc7a9c4580c0dd239bcf93587baa.pdf"
            },
            {
                "text": "ID487509095708-0101.pdf",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/f2/0d/f20d0381f0c0ea0d38010f7a09b58634e9d309ea85dc6e3ba20dec201677729a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/f2/0d/f20d0381f0c0ea0d38010f7a09b58634e9d309ea85dc6e3ba20dec201677729a.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5702422020400"
        },
        "description": "Used for product: T 2; TE 2, Parts Program name: T2/TE2, Packing format: Multi pack, Quantity per packing format: 25",
        "created_at": "2026-06-14 00:05:24",
        "variations": []
    }
}