    "data": {
        "id": 74219,
        "sku": "132X3708",
        "name": "IC7-60FA3N05-73A0E21F1+ACBC+ALDC+BAPR+BDBA+BEF1+BF20+DAAU",
        "manufacturer": "Danfoss",
        "product_url": "https://store.danfoss.com/us/en_US/p/132X3708",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 923,
            "name": "iC7-Automation Frequency Converter"
        },
        "categories": [
            {
                "id": 923,
                "name": "iC7-Automation Frequency Converter"
            }
        ],
        "series": null,
        "specifications": {
            "Gross weight": "33.78 Kilogram",
            "Net weight": "28.84 Kilogram",
            "Volume": "91.654 Liter",
            "EAN": "5715253186245",
            "Product series": "+DAAU, iC7-Automation",
            "Product group": "IC7-60, iC7-60",
            "Product category": "FA, Frequency converter,air-cooled",
            "Product type": "3N, 3~",
            "Mains voltage": "05, 380-500 V AC",
            "Current rating": "-73A0, 73 A",
            "Power rating": "37K, 37 kW/50 hp",
            "Protection rating": "E21, IP21/UL Type 1",
            "EMC category": "F1, C1 and C2 category",
            "Cable entry and EMC plate": "+AAST, Standard plate",
            "Integrated brake chopper": "+ACBC, Yes",
            "Extra environmental protection": "+AGXX, None",
            "Humidity protection device": "+AHXX, None",
            "Integrated common-mode filter": "+AIXX, None",
            "Mains input device": "+AJXX, None",
            "DC terminals": "+ALDC, Yes",
            "Touch protection": "+AMXX, None",
            "Heat sink access panel": "+APXX, None",
            "Communication interface, X1/X2": "+BAPR, PROFINET RT OS7PR",
            "Communication interface, X0": "+BBEL, Ethernet port, no protocol",
            "Standard I/O": "+BDBA, 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO",
            "Functional safety": "+BEF1, STO, not upgradable",
            "Control panel": "+BF20, Control Panel 2.8 OPX20",
            "Interface board": "+BISR, MicroSD card reader and RTC",
            "Option slot A": "+CAX0, None",
            "Option slot B": "+CBXX, None, not upgradable",
            "Option slot C": "+CCX0, None",
            "Option slot D": "+CDX0, None",
            "Option Slot E": "+CEX0, None",
            "Customer specific application": "+DBXX, None",
            "Additional drive features 1": "+DD1X, None",
            "Additional drive features 2": "+DE2X, None",
            "Additional drive features 3": "+DF3X, None",
            "Additional drive features 4": "+DG4X, None",
            "Additional drive features 5": "+DH5X, None",
            "High speed enabled": "+DI6X, No",
            "Customization file package ID": "+EAXXXXXX, No customization",
            "Product software ID": "+ECXXX, Latest released version",
            "Technical documentation": "+EGIN, Installation guide",
            "Customer-specific label": "+EJXX, None",
            "Language package": "+EL01, Global",
            "Product specific marine cert.": "+VBXX, None",
            "Frame designation": "FK06, FK06",
            "Control Board type": "A5E, Advanced Ethernet A5E",
            "Modelcode01": "IC7-60FA3N05-73A0E21F1",
            "Modelcode02": "+ACBC",
            "Modelcode03": "+ALDC+BAPR+BDBA",
            "Modelcode04": "+BEF1+BF20",
            "Modelcode05": "+DAAU",
            "Input Voltage": "3x380-500V, 3x380-500V",
            "Input frequency": "50/60Hz, 50/60Hz",
            "Short circuit current rating": "100kA, 100kA",
            "Output frequency": "0-590Hz, 0-590Hz",
            "Typical motor power PL (110%)": "37kW(400V)/50HP(460V), 37kW(400V)/50HP(460V)",
            "Continous current IL (1/10min)": "73/66A, 73/66A",
            "Overload current IL (1/10min)": "80/73A, 80/73A",
            "Input current LO (1/10 min)": "70/61A, 70/61A",
            "Ambient temp LO (1/10 min)": "45°C/113°F, 45°C/113°F",
            "Typical motor power PH (150%)": "37KW(400V)/50HP(460V), 37KW(400V)/50HP(460V)",
            "Continous current IH (1/10min)": "73/66A, 73/66A",
            "Overload current IH (1/10min)": "110/99A, 110/99A",
            "Input current HO (1/10 min)": "70/61A, 70/61A",
            "Ambient temp HO (1/10 min)": "45°C/113°F, 45°C/113°F",
            "Typical motor power PH2 (150%)": "30kW(400V)/40HP(460V), 30kW(400V)/40HP(460V)",
            "Continous current IH (1/5min)": "61/55A, 61/55A",
            "Overload current IH (1/5min)": "92/83A, 92/83A",
            "Input curent HO2 (1/5 min)": "57/50A, 57/50A",
            "Ambient temp HO2 (1/5 min)": "45°C/113°F, 45°C/113°F",
            "Efficiency class-Relative loss": "IE2 - 1.52%, IE2 - 1.52%",
            "Maximum Power Loss LO [W]": "817, 817",
            "Main unit Width": "209 mm / 8.2 in, 209 mm / 8.2 in",
            "Main unit Height": "671 mm / 26.4 in, 671 mm / 26.4 in",
            "Main unit Depth": "303 mm / 11.9 in, 303 mm / 11.9 in",
            "Calculated Net Weight [kg]": "28.84",
            "Calculated Gross Weight [kg]": "33.78",
            "ECCN EU": "Y901, Y901",
            "ECCN US": "3A999.a, 3A999.a",
            "Ambient temp. normal overload": "45°C/113°F, 45°C/113°F",
            "Enclosure rating": "IP21 / TYPE 1, IP21 / TYPE 1",
            "Help Counter": "1",
            "High Speed Drive Warning": "NONE, NONE",
            "Input current in Normal Overlo": "70/61A, 70/61A",
            "Product Catalog": "NO_VIEW, NO VIEW",
            "Product View (Switch)": "GLBL, Global (Standard)",
            "Recommended Plant": "ERR01, ERR01",
            "Typecode Part 1": "7FC-AUFA3N05-73A0E21F1",
            "Typecode Part 2": "-000046575",
            "Vendor": "ERR01, Cannot Determine Vendor"
        },
        "images": [
            {
                "src": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/56/03/56031cf5da8acbcfd505c2c82d5be0f63c0245f98455e406e1fd353307169801.jpg",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/images/56/03/56031cf5da8acbcfd505c2c82d5be0f63c0245f98455e406e1fd353307169801.jpg",
                "local_path": "danfoss/images/56/03/56031cf5da8acbcfd505c2c82d5be0f63c0245f98455e406e1fd353307169801.jpg",
                "original_url": "https://assets.danfoss.com/photos/357253/ID471667124358-0101.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Connecting to iC7 Series Remotely via Mobile Network",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/36/f1/36f1423a6f5206ae072b621846a5b400360790dea68983d0db4764d14f364895.pdf"
            },
            {
                "text": "iC7 integration into Siemens TIA Portal",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/9a/41/9a41bcc8535ca23aec8ba9c454863e6e593fbbbd5e33659821c6eb8b036d3a7d.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/9a/41/9a41bcc8535ca23aec8ba9c454863e6e593fbbbd5e33659821c6eb8b036d3a7d.pdf"
            },
            {
                "text": "iC7 Series Industry; Software version 26A",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/57/93/5793442054592524eb5aea4fb9fbb6aae67086d5748cb1c5cf3d81e10dde5696.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/57/93/5793442054592524eb5aea4fb9fbb6aae67086d5748cb1c5cf3d81e10dde5696.pdf"
            },
            {
                "text": "iC7-Automation Use-of DC Connections",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/4a/7e/4a7e4bf3324941b62c8a76b82fb3ae0dda8adc4111ff8ccc94f24bfd2d64da9a.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/4a/7e/4a7e4bf3324941b62c8a76b82fb3ae0dda8adc4111ff8ccc94f24bfd2d64da9a.pdf"
            },
            {
                "text": "MyDrive Insight for iC7; SW 2.20.0",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/cb/df/cbdf4cead8851e40f163ce441a65c9b72ec57a3242ca90c2cdd479fdb2b31220.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/cb/df/cbdf4cead8851e40f163ce441a65c9b72ec57a3242ca90c2cdd479fdb2b31220.pdf"
            },
            {
                "text": "MyDrive Insight Logic Feature",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1a/18/1a18521f1cb96543b892c1ba010f919c6b55d6d8fb7083d5818ad7ebfdddaa13.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1a/18/1a18521f1cb96543b892c1ba010f919c6b55d6d8fb7083d5818ad7ebfdddaa13.pdf"
            },
            {
                "text": "Simulation with iC7 Virtual Industry Application Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/ac/97/ac97523842f7eac5e944f644364e5fa65aa1d80396e38b31e1958e6adc00fa67.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/ac/97/ac97523842f7eac5e944f644364e5fa65aa1d80396e38b31e1958e6adc00fa67.pdf"
            },
            {
                "text": "iC7-Automation Selection Guide",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/3c/c3/3cc3923021469c6a3f73cd6ad6a92a6b562758799b56000e299a6a24330c8ba3.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/3c/c3/3cc3923021469c6a3f73cd6ad6a92a6b562758799b56000e299a6a24330c8ba3.pdf"
            },
            {
                "text": "iC7-Automation Selection Guide - US English",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/1c/1f/1c1f1b3326c1086c18c7fd1ccf0b44486457d4488969c9a538a55cb655e3e3fc.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/1c/1f/1c1f1b3326c1086c18c7fd1ccf0b44486457d4488969c9a538a55cb655e3e3fc.pdf"
            },
            {
                "text": "iC7-Automation Frequency Converters",
                "type": "document",
                "url": "https://danfoss.weareindata.com/downloaded_assets/danfoss/pdfs/23/e5/23e54ec90ddf88aa04115e7aa6a9417edbd539f7b4dcca1065baec1ff7f73f21.pdf",
                "original_url": null,
                "local_path": "danfoss/pdfs/23/e5/23e54ec90ddf88aa04115e7aa6a9417edbd539f7b4dcca1065baec1ff7f73f21.pdf"
            }
        ],
        "custom_fields": {
            "gtin": "5715253186245"
        },
        "description": "iC7-Automation Frequency converter,air-cooled IC7-60FA3N05-73A0E21F1+ACBC +ALDC+BAPR+BDBA+BEF1+BF20 +DAAU IP21/UL Type 1, Frame: FK06 3~, 380-500 V AC, 73 A EMC category: C1 and C2 category Control Panel 2.8 OPX20 Standard I/O: 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO Fieldbus protocols enabled: PROFINET RT OS7PR Other protocols enabled: Ethernet port, no protocol Functional Safety: STO, not upgradable Other options according to model code",
        "created_at": "2026-06-16 07:35:45",
        "variations": []
    }
}