Attributes
| Gtin | 5715162673447 |
|---|
Description
Mounting orientation: Horizontal, HP out flow [m³/h] [Max]: 41, HP out flow [gpm] [Max]: 181, Rated power [HP]: 15, Rated power [kW]: 11
Specifications
| Gross weight | 342 Kilogram |
|---|---|
| Net weight | 300 Kilogram |
| Volume | 669.9 Liter |
| EAN | 5715162673447 |
| Type | iSave 40 |
| Product group | Energy Recovery Device |
| Allowable working torque [lbf·ft] [Max] | 75 lbf∙ft |
| Allowable working torque [Nm] [Max] | 102 N-m |
| Ambient temperature [°C] [Max] | 50 °C |
| Ambient temperature [°C] [Min] | 0 °C |
| Ambient temperature [°F] [Max] | 122 °F |
| Ambient temperature [°F] [Min] | 32 °F |
| Approval | CE |
| Base frame | Stainless |
| CE evaluated | Yes |
| China RoHS compliance | Out of scope |
| Contains batteries | No |
| Country of origin | Denmark |
| Description | iSave with IEC motor |
| Differential pressure HP in out [barg] [Max] | 5 barg |
| Differential pressure HP in out [psig] [Max] | 72 psig |
| Drain connection size [in] | 1/4 in |
| Drain connection standard | BSPP |
| Drain connection type | BSPP |
| EU RoHS compliance | Yes |
| EU RoHS exemption clause | No |
| Flow [gpm] [Min] | 92 gal/min |
| Flow [m³/h] [Min] | 21 m³/h |
| HP inlet connection size [in] | 3 in |
| HP Inlet connection standard | Victaulic |
| HP inlet pressure [barg] [Max] | 83 barg |
| HP inlet pressure [barg] [Min] | 20 barg |
| HP inlet pressure [psig] [Max] | 1200 psig |
| HP inlet pressure [psig] [Min] | 290 psig |
| HP inlet pressure, intermittent [barg] [Min] | 3 barg |
| HP inlet pressure, intermittent [psig] [Min] | 44 psig |
| HP out flow [gpm] [Max] | 181 gal/min |
| HP out flow [m³/h] [Max] | 41 m³/h |
| HP outlet connection size [in] | 3 in |
| HP Outlet connection standard | Victaulic |
| HP outlet pressure [barg] [Max] | 83 barg |
| HP outlet pressure [psig] [Max] | 1200 psig |
| In scope of WEEE | No |
| IP protection class | IP55 |
| LP in out @ max flow [psig] | 18 psig |
| LP in out @ max. flow [barg] | 1 barg |
| LP inlet allowable working flow [gpm] [Max] | 295 gal/min |
| LP inlet allowable working flow [m³/h] [Max] | 67 m³/h |
| LP inlet connection size [in] | 3 in |
| LP Inlet connection standard | Victaulic |
| LP inlet pressure [barg] [Max] | 5 barg |
| LP inlet pressure [psig] [Max] | 72 psig |
| LP Inlet pressure peak [barg] | 10 barg |
| LP Inlet pressure peak [psig] | 145 psig |
| LP outlet connection size [in] | 3 in |
| LP outlet pressure [barg] [Min] | 1 barg |
| LP outlet pressure [psig] [Min] | 15 psig |
| Lubrication flow at 60 [m³/h] [Max] | 0.8 m³/h |
| Lubrication flow at 871 [gpm] [Max] | 3.5 gal/min |
| Material type | Duplex, Super Duplex |
| Media temperature [°C] [Max] | 40 °C |
| Media temperature [°C] [Min] | 2 °C |
| Media temperature [°F] [Max] | 104 °F |
| Media temperature [°F] [Min] | 36 °F |
| Motor ambient temperature [°C] [Max] | 40 °C |
| Motor ambient temperature [°F] [Max] | 104 °F |
| Motor current [A] | 22 A |
| Motor frame Size | 160L |
| Motor insulation class | B |
| Motor poles | 6 |
| Motor standard | IEC |
| Motor torque at min. speed [lbf·ft] | 70 lbf∙ft |
| Motor torque at min. speed [Nm] | 95 N-m |
| Motor Torque at nom. speed [lbf·ft] | 80 lbf∙ft |
| Motor torque at nom. speed [Nm] | 108 N-m |
| Motor voltage | 380-420V/660720V, 50 Hz, 440-480V, 60 Hz |
| Mounting orientation | Horizontal |
| Outside dimensions of packaging LxWxH [in] | 57,3x20,8x29 |
| Outside dimensions of packaging LxWxH [mm] | 1460x530x740 |
| Product description | iSave |
| Rated power [HP] | 15 HP |
| REACH Candidate List substances | No |
| Seal Material | NBR |
| Serviceable | Yes |
| Sound pressure level [dB(A)] | 84 dBA |
| Speed [rpm] [Max] | 1200 rpm |
| Speed [rpm] [Min] | 600 rpm |
| Starting torque [lbf·ft] [Max] | 110 lbf∙ft |
| Starting torque [Nm] [Max] | 150 N-m |
| Type designation | ISAVE 40 |
| UL evaluated | No |
PDF Documents
Danfoss iSave® ERDs at the heart of new, high-end containerized SWRO units
Open PDF
Krosys saves energy and maintenance costs while processing unique “lava water”
Open PDF
Low energy and maintenance costskey to success at plant in Bermuda
Open PDF
NTesco chooses Danfoss for high-efficiency SWRO at Vietnamese shrimp farm
Open PDF
SUEZ chooses oil-free Danfoss APP pump to power Bahaman RO plant retrofit
Open PDF
iSave 21 Plus and iSave 40 Data sheet
Open PDF
APP and iSave overload protection
Open PDF
Membrane cleaning of the RO-system with iSave ERD
Open PDF
Parallel coupled APP pumps and iSave energy recovery device
Open PDF
Piping connections
Open PDF